SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:33f1d137-274f-4374-a6be-74cbf9a233a4"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:33f1d137-274f-4374-a6be-74cbf9a233a4" > Conversion of sodiu...

Conversion of sodium lactate to lactic acid with water-splitting electrodialysis

Persson, A (författare)
Garde, A (författare)
Jönsson, Ann-Sofi (författare)
Lund University,Lunds universitet,Avdelningen för kemiteknik,Institutionen för processteknik och tillämpad biovetenskap,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Chemical Engineering,Department of Process and Life Science Engineering,Departments at LTH,Faculty of Engineering, LTH
visa fler...
Jonsson, G (författare)
Zacchi, Guido (författare)
Lund University,Lunds universitet,Avdelningen för kemiteknik,Institutionen för processteknik och tillämpad biovetenskap,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Chemical Engineering,Department of Process and Life Science Engineering,Departments at LTH,Faculty of Engineering, LTH
visa färre...
 (creator_code:org_t)
2001
2001
Engelska.
Ingår i: Applied Biochemistry and Biotechnology. - 1559-0291. ; 94:3, s. 197-211
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The conversion of sodium lactate to lactic acid with water-splitting electrodialysis was investigated. One way of reducing the power consumption is to add a conductive layer to the acid compartment. Doing this reduced the power consumption by almost 50% in a two-compartment cell, whereas the electric current efficiency was not affected at all. Three different solutions were treated in the electrodialysis unit: a model solution with 70 g/L of sodium lactate and a fermentation broth that had been prefiltered two different ways. The fermentation broth was either filtered in an open ultrafiltration membrane (cut-off of 100,000 Dalton) in order to remove the microorganisms or first filtered in the open ultrafiltration membrane and then in an ultrafiltration membrane with a cut-off of 2000 Dalton to remove most of the proteins. The concentration of sodium lactate in the fermentation broth was 70 g/L, as well. Organic molecules present in the broth (peptides and similar organic material) fouled the membranes and, therefore, increased power consumption. Power consumption increased more when permeate from the more open ultrafiltration membrane was treated in the electrodialysis unit than when permeate from the membrane with the lower cut-off was treated, since there was a higher amount of foulants in the former permeate. However, the electrodialysis membranes could be cleaned efficiently with a 0.1 M sodium hydroxide solution.

Ämnesord

NATURVETENSKAP  -- Biologi -- Biokemi och molekylärbiologi (hsv//swe)
NATURAL SCIENCES  -- Biological Sciences -- Biochemistry and Molecular Biology (hsv//eng)

Nyckelord

lactic acid
electrodialysis
bipolar membranes
fermentation broth
wheat

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Persson, A
Garde, A
Jönsson, Ann-Sof ...
Jonsson, G
Zacchi, Guido
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Biologi
och Biokemi och mole ...
Artiklar i publikationen
Applied Biochemi ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy