Sökning: id:"swepub:oai:lup.lub.lu.se:35177c9d-5704-47ef-9bf8-13f3b0ae69d1" >
B-field energy depe...
B-field energy dependent phase lag dispersion in magnetomotive ultrasound imaging
-
- Andersson, Roger (författare)
- Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
-
- Cinthio, Magnus (författare)
- Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
-
- Evertsson, Maria (författare)
- Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
-
visa fler...
-
Toftevall, Hanna (författare)
-
Wahlstrom, Anders (författare)
-
Fredriksson, Sarah (författare)
-
Nybom, Goran (författare)
-
- Jansson, Tomas (författare)
- Lund University,Lunds universitet,Medicinsk teknik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Biomedical Engineering, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Skåne University Hospital
-
visa färre...
-
(creator_code:org_t)
- 2015
- 2015
- Engelska 4 s.
-
Ingår i: 2015 IEEE International Ultrasonics Symposium (IUS). - 1948-5719.
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Magnetomotive ultrasound imaging is an emerging technique where superparamagnetic iron oxide nanoparticles can be used as an ultrasound contrast agent. A time-varying external magnetic field acts to move tissue embedded particles, and ultrasound is used to detect the resulting tissue movement. In experimental phantom studies we have observed a phase lag dispersion in the magnetomotive response in respect to applied time-varying magnetic field (B-field). We hypothesize that this dispersion is triggered by the strength of the applied B-field in combination with concentration of embedded nanoparticles in the region. The cohort response of the nanoparticles aligns as the magnetic field gets more energetic. Moreover, the tightening of the phase response indicate an asymptotic tapering towards a phase limit.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
Nyckelord
- molecular imaging
- contrast agents
- superparamagnetic
- iron oxide
- nanoparticles
Publikations- och innehållstyp
- kon (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas