Accuracy of QT Measurement in the EASI-derived 12-lead ECG

Martinez, J P (författare)
Laguna, P (författare)
Olmos, S (författare)
visa fler...
Pahlm, Olle (författare)
Lund University,Lunds universitet,Klinisk fysiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Clinical Physiology (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Petersson, J (författare)
Sörnmo, Leif (författare)
Lund University,Lunds universitet,Institutionen för elektro- och informationsteknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Electrical and Information Technology,Departments at LTH,Faculty of Engineering, LTH
visa färre...
 (creator_code:org_t)
2006
2006
Engelska 4 s.
Ingår i: Conference proceedings (IEEE Engineering in Medicine and Biology Society. Conf.). - 1557-170X. ; 1, s. 3986-3989
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • The purpose of this study is to assess QT interval measurements from the EASI 12-lead ECG as compared to the standard 12-lead ECG. The QT interval was automatically measured in simultaneously recorded standard and EASI 12- lead ECGs, using a validated wavelet-based delineator. The agreement between the two sets of measurements was quantified both on a lead-by-lead basis and a multilead basis. The results show an acceptable agreement between QT measurements in the two lead systems, with correlation coefficients (CC) 0.91-0.98 depending on the lead. Standard deviations range from 9.2 ms to 26.4 ms depending on the selected lead. In a few patients large inter-system differences were found, mainly due to different T wave morphologies. Using a multilead delineation, QT intervals were considerably more stable than single-lead measurements and resulted in a much better agreement between the two lead systems (CC: 0.98, QT difference: 1.1 ms ± 9.8 ms). Thus, EASI-derived 12- lead ECG may be used for reliable QT monitoring when the multilead delineation approach is adopted.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Lungmedicin och allergi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Respiratory Medicine and Allergy (hsv//eng)

Publikations- och innehållstyp

kon (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Martinez, J P
Laguna, P
Olmos, S
Pahlm, Olle
Petersson, J
Sörnmo, Leif
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Kardiologi
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Lungmedicin och ...
Artiklar i publikationen
Conference proce ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy