Nanofluidic analytical system integrated with nanochannel open/close valves for enzyme-linked immunosorbent assay

Sano, Hiroki (författare)
University of Tokyo
Kazoe, Yutaka (författare)
Keio University
Ohta, Ryoichi (författare)
University of Tokyo
visa fler...
Shimizu, Hisashi (författare)
University of Tokyo
Morikawa, Kyojiro (författare)
University of Tokyo,National Tsing Hua University
Kitamori, Takehiko (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,LTH profilområde: Teknik för hälsa,LTH profilområden,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH,LTH Profile Area: Engineering Health,LTH Profile areas,Faculty of Engineering, LTH,National Tsing Hua University,University of Tokyo
visa färre...
 (creator_code:org_t)
2023
2023
Engelska 10 s.
Ingår i: Lab on a Chip. - : Royal Society of Chemistry (RSC). - 1473-0197 .- 1473-0189. ; 23, s. 727-736
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • There have been significant advances in the field of nanofluidics, and novel technologies such as single-cell analysis have been demonstrated. Despite the evident advantages of nanofluidics, fluid control in nanochannels for complicated analyses is extremely difficult because the fluids are currently manipulated by maintaining the balance of driving pressure. To address this issue, the use of valves will be essential. Our group previously developed a nanochannel open/close valve utilizing glass deformation, but this has not yet been integrated into nanofluidic devices for analytical applications. In the present study, a nanofluidic analytical system integrated with multiple nanochannel open/close valves was developed. This system consists of eight pneumatic pumps, seven nanochannel open/close valves combined with piezoelectric actuators, and an ultra-high sensitivity detector for non-fluorescent molecules. For simultaneous actuation of multiple valves, a device holder was designed that prevented deformation of the entire device caused by operating the valves. A system was subsequently devised to align each valve and actuator with a precision of better than 20 μm to permit the operation of valves. The developed analytical system was verified by analyzing IL-6 molecules using an enzyme-linked immunosorbent assay. Fluid operations such as sample injection, pL-level aliquot sampling and flow switching were accomplished in this device simply by opening/closing specific valves, and a sample consisting of approximately 1500 IL-6 molecules was successfully detected. This study is expected to significantly improve the usability of nanofluidic analytical devices and lead to the realization of sophisticated analytical techniques such as single-cell proteomics.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinsk bioteknologi -- Biomedicinsk laboratorievetenskap/teknologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Medical Biotechnology -- Biomedical Laboratory Science/Technology (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy