SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:3d9a78c7-f66a-48c9-9920-ea7c44b1e121"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:3d9a78c7-f66a-48c9-9920-ea7c44b1e121" > Localization of emb...

Localization of embedded inclusions using detection of fluorescence: Feasibility study based on simulation data, LS-SVM modeling and EPO pre-processing

Chauchard, Fablen (författare)
Svensson, Jenny (författare)
Lund University,Lunds universitet,Atomfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Atomic Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
Axelsson, Johan (författare)
Lund University,Lunds universitet,Atomfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Atomic Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
visa fler...
Andersson-Engels, Stefan (författare)
Lund University,Lunds universitet,Atomfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Atomic Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
Roussel, Sylvie (författare)
visa färre...
 (creator_code:org_t)
Elsevier BV, 2008
2008
Engelska.
Ingår i: Chemometrics and Intelligent Laboratory Systems. - : Elsevier BV. - 0169-7439. ; 91:1, s. 34-42
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Fluorescence spectroscopy is a useful technique for tissue diagnostics and is also a promising tool in the characterization of embedded structures in tissue. The emitted fluorescence from an embedded inclusion, marked with a fluorescent compound, is affected by several factors as the light propagates through the medium to the tissue boundary, where the fluorescence light is detected. Tissue absorption, scattering and autofluorescence, as well as the size and depth of the inclusion, affect the detected fluorescence light. The aim of this study is to investigate if the size and location of a fluorescent inclusion could be determined using models based a combination of External Parameter Orthogonalisation (EPO) and Least Squares Support Vector Machine (LS-SVM). This can be very useful for data pre-processing before a full fluorescence tomography reconstruction. The data set consisted of simulated multispectral fluorescence, where depth and radius of a spherical fluorescent inclusion were varied as well as the fluorescence contrast and optical properties of the surrounding tissue. The results showed that the non-linear models based on LS-SVM can simultaneously predict both radius and depth. It was observed that EPO acts as a useful pre-processing tool on spectra for this nonlinear model and that it was necessary to perform EPO to be able to predict the depth with the LS-SVM model. (C) 2007 Elsevier B.V. All rights reserved.

Ämnesord

NATURVETENSKAP  -- Fysik -- Atom- och molekylfysik och optik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Atom and Molecular Physics and Optics (hsv//eng)

Nyckelord

embedded
non-linearity
LS-SVM
external parameter orthogonalisation
multivariate analysis
multispectral
fluorescence spectroscopy
lesions
fluorescence tomography

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy