SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:4109dddd-2c8d-4817-9dd9-a6deb17c0cc5"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:4109dddd-2c8d-4817-9dd9-a6deb17c0cc5" > A Novel Anthropomor...

A Novel Anthropomorphic Phantom Composed of Tissue-Equivalent Materials for Use in Experimental Radiotherapy : Design, Dosimetry and Biological Pilot Study

Breslin, Thomas (författare)
Lund University,Lunds universitet,LUCC: Lunds universitets cancercentrum,Övriga starka forskningsmiljöer,Strålterapi,Sektion I,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,LUCC: Lund University Cancer Centre,Other Strong Research Environments,Radiation therapy,Section I,Department of Clinical Sciences, Lund,Faculty of Medicine
Paino, Jason (författare)
University of Wollongong
Wegner, Marie (författare)
Hamburg University of Technology
visa fler...
Engels, Elette (författare)
University of Wollongong,Australian Synchrotron
Fiedler, Stefan (författare)
European Molecular Biology Laboratory Hamburg
Forrester, Helen (författare)
RMIT University
Rennau, Hannes (författare)
Universitätsmedizin Rostock
Bustillo, John (författare)
University of Wollongong
Cameron, Matthew (författare)
Australian Synchrotron
Häusermann, Daniel (författare)
Australian Synchrotron
Hall, Christopher (författare)
Australian Synchrotron
Krause, Dieter (författare)
Hamburg University of Technology
Hildebrandt, Guido (författare)
Universitätsmedizin Rostock
Lerch, Michael (författare)
University of Wollongong
Schültke, Elisabeth (författare)
Universitätsmedizin Rostock
visa färre...
 (creator_code:org_t)
2023
2023
Engelska.
Ingår i: Biomimetics. - 2313-7673. ; 8:2
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The production of anthropomorphic phantoms generated from tissue-equivalent materials is challenging but offers an excellent copy of the typical environment encountered in typical patients. High-quality dosimetry measurements and the correlation of the measured dose with the biological effects elicited by it are a prerequisite in preparation of clinical trials with novel radiotherapy approaches. We designed and produced a partial upper arm phantom from tissue-equivalent materials for use in experimental high-dose-rate radiotherapy. The phantom was compared to original patient data using density values and Hounsfield units obtained from CT scans. Dose simulations were conducted for broad-beam irradiation and microbeam radiotherapy (MRT) and compared to values measured in a synchrotron radiation experiment. Finally, we validated the phantom in a pilot experiment with human primary melanoma cells.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

anthropomorphic phantom
CT scan
dosimetry
experimental radiotherapy
microbeam radiotherapy (MRT)
therapy planning
tissue-equivalent materials

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy