SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:41e50dc1-e227-4aec-aeb3-e79a1ced95c1"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:41e50dc1-e227-4aec-aeb3-e79a1ced95c1" > Echo time dependenc...

Echo time dependence of biexponential and triexponential intravoxel incoherent motion parameters in the liver

Führes, Tobit (författare)
University Hospital Erlangen
Riexinger, Andreas Julian (författare)
University Hospital Erlangen
Loh, Martin (författare)
University Hospital Erlangen
visa fler...
Martin, Jan (författare)
Lund University,Lunds universitet,Fysikalisk kemi,Enheten för fysikalisk och teoretisk kemi,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Physical Chemistry,Physical and theoretical chemistry,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
Wetscherek, Andreas (författare)
Royal Marsden NHS Foundation Trust
Kuder, Tristan Anselm (författare)
German Cancer Research Centre
Uder, Michael (författare)
University Hospital Erlangen
Hensel, Bernhard (författare)
Friedrich-Alexander University Erlangen-Nürnberg
Laun, Frederik Bernd (författare)
University Hospital Erlangen
visa färre...
 (creator_code:org_t)
2021-08-28
2022
Engelska.
Ingår i: Magnetic Resonance in Medicine. - : Wiley. - 0740-3194 .- 1522-2594. ; 87:2, s. 859-871
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose: Intravoxel incoherent motion (IVIM) studies are performed with different acquisition protocols. Comparing them requires knowledge of echo time (TE) dependencies. The TE-dependence of the biexponential perfusion fraction f is well-documented, unlike that of its triexponential counterparts f1 and f2 and the biexponential and triexponential pseudodiffusion coefficients D*, (Formula presented.), and (Formula presented.). The purpose was to investigate the TE-dependence of these parameters and to check whether the triexponential pseudodiffusion compartments are associated with arterial and venous blood. Methods: Fifteen healthy volunteers (19-58 y; mean: 24.7 y) underwent diffusion-weighted imaging of the abdomen with 24 b-values (0.2-800 s/mm2) at TEs of 45, 60, 75, and 90 ms. Regions of interest (ROIs) were manually drawn in the liver. One set of bi- and triexponential IVIM parameters per volunteer and TE was determined. The TE-dependence was assessed with the Kruskal-Wallis test. Results: TE-dependence was observed for f (P <.001), f1 (P =.001), and f2 (P <.001). Their median values at the four measured TEs were: f: 0.198/0.240/0.274/0.359, f1: 0.113/0.139/0.146/0.205, f2: 0.115/0.155/0.182/0.194. D, D*, (Formula presented.), and (Formula presented.) showed no significant TE-dependence. Their values were: diffusion coefficient D (10−4 mm2/s): 9.45/9.63/9.75/9.41, biexponential D* (10−2 mm2/s): 5.26/5.52/6.13/5.82, triexponential (Formula presented.) (10−2 mm2/s): 1.73/2.91/2.25/2.51, triexponential (Formula presented.) (mm2/s): 0.478/1.385/0.616/0.846. Conclusion: f1 and f2 show similar TE-dependence as f, ie, increase with rising TE; an effect that must be accounted for when comparing different studies. The diffusion and pseudodiffusion coefficients might be compared without TE correction. Because of the similar TE-dependence of f1 and f2, the triexponential pseudodiffusion compartments are most probably not associated to venous and arterial blood.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

diffusion
echo time
IVIM
liver
perfusion

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy