SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:432095a6-1e38-43b2-8689-cc9998c5dd00"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:432095a6-1e38-43b2-8689-cc9998c5dd00" > Experimentally dete...

Experimentally determined vs. Monte Carlo simulated peak-to-valley ratios for a well-characterised n-type HPGe detector.

Östlund, Karl (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
Samuelsson, Christer (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
Rääf, Christopher (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
 (creator_code:org_t)
Elsevier BV, 2015
2015
Engelska.
Ingår i: Applied Radiation and Isotopes. - : Elsevier BV. - 0969-8043. ; 95, s. 94-100
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Measurements and simulations to investigate the contributing factors to the peak-to-valley (PTV) ratio have been both experimentally determined as well as Monte Carlo simulated for a well-characterised HPGe n-type detector together with a Cs-137 gamma source encapsulated in thin polystyrene. Measurements were carried out in a low-background gamma counting facility at Lund University. The results of the PTV ratio have been compared to distinguish what components or variables in the setup that significantly influence the ratio. In addition to manufacture specifications, the detector components have been examined using planar X-ray, source scanning and computer tomography in order to determine and verify component dimensions when necessary. In spite of these efforts a discrepancy of approximately 25% for thin absorbers in the PTV ratio between measurements and calculations is observed. However, this discrepancy becomes less significant for larger absorbing layers of copper (>1mm). This indicates that it would be difficult to achieve a field calibration for in-situ gamma spectrometry using the PTV ratio that could position a Cs-137 source in soil depth shallower than corresponding 1mm layer of copper. The results also showed that when building a detector in simulations part by part, the inner dead layer, and the contact pin are of great importance for the accuracy of the PTV ratio simulations.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Östlund, Karl
Samuelsson, Chri ...
Rääf, Christophe ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Applied Radiatio ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy