SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:445a54bc-3739-4941-8963-3341f25f4e51"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:445a54bc-3739-4941-8963-3341f25f4e51" > Determination of bo...

Determination of both the time constant of vO and DeltavO/DeltaW from a single incremental exercise test: validation and repeatability.

Wisén, Anita (författare)
Lund University,Lunds universitet,Människan i rörelse: hälsa och rehabilitering,Forskargrupper vid Lunds universitet,Human Movement: health and rehabilitation,Lund University Research Groups
Wohlfart, Björn (författare)
Lund University,Lunds universitet,Klinisk fysiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Clinical Physiology (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
 (creator_code:org_t)
2004
2004
Engelska.
Ingår i: Clinical Physiology and Functional Imaging. - 1475-0961. ; 24:5, s. 257-265
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A single incremental cycle exercise test including a steady-state load, combined with respiratory gas exchange, was performed with the objective of determining the time constant (o2) and the amount of oxygen required at each load (o2/DeltaW) by using a novel equation. The protocol was validated using four exercise tests at different constant loads and conventionally fitted mono-exponential functions to determine o2, and interpolation of o2 versus load to determine o2/DeltaW. No significant differences were seen between the means of either o2 or o2/DeltaW determined with the two protocols. The correlation coefficient was 0·62 for o2 and 0·48 for o2/DeltaW. The absolute differences (2 SD) were 11·6 s for o2 and 1·1 ml min-1 W-1 for o2/DeltaW. The equations were compared in the same steady-state test and good agreement of o2 was obtained (R = 0·99). The 5-6-week repeatability (incremental test) was evaluated. No statistical differences were seen between the mean of the repeated tests. The difference between the tests (2 SD) were 20 s for o2 and 1·2 ml min-1 W-1 for o2/DeltaW. In conclusion, o2 and o2/DeltaW can be determined from a single incremental test. The validation showed an acceptable agreement, although the variations in absolute values were not negligible. This could partly be explained by the natural day-to-day variation and fluctuations in incoming raw data. The test-retest variation in absolute values was considerable, which must be taken into account when using o2 and o2/DeltaW for evaluation of aerobic function.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Fysiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Physiology (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Wisén, Anita
Wohlfart, Björn
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Medicinska och f ...
och Fysiologi
Artiklar i publikationen
Clinical Physiol ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy