Sökning: id:"swepub:oai:lup.lub.lu.se:4737fcec-a18d-47c3-9664-80afc675ca66" >
Simple hollow fiber...
Simple hollow fiber liquid membrane based pre-concentration of silver for atomic absorption spectrometry
-
Antonio Lopez-Lopez, Jose (författare)
-
- Jönsson, Jan Åke (författare)
- Lund University,Lunds universitet,Centrum för analys och syntes,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Centre for Analysis and Synthesis,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
-
Garcia-Vargas, Manuel (författare)
-
visa fler...
-
Moreno, Carlos (författare)
-
visa färre...
-
(creator_code:org_t)
- 2014
- 2014
- Engelska.
-
Ingår i: Analytical Methods. - : Royal Society of Chemistry (RSC). - 1759-9660. ; 6:5, s. 1462-1467
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Silver pollution has gained attention in the last few years because silver is being massively used as a bactericide in self-care, medical and textile products. Difficulties of Ag determination are associated with the very low concentrations in which it is normally found (ng L-1) and the nature of the sample matrix. Standard methods such as liquid-liquid extraction (LLE) are regularly used. Alternatively, liquid phase micro-extraction (LPME) appears to be an environmentally friendly tool for sample treatment that offers higher pre-concentration factors. This allows the determination of ultra-trace levels of silver using standard instrumental techniques such as atomic absorption spectrometry. In this work, a hollow fiber LPME is proposed. Silver pre-concentration has been conducted using tri-isobutylphosphine sulphide (TIBPS) as a carrier from the sample to an acceptor solution through a solvent placed in the fiber pores. Accurel-PP 50/280 fibers with an internal volume of 20 mu L were used for 50 mL samples. After optimization, 0.1 M KNO3 in the sample, 0.1 M TIBPS in dihexyl ether as the organic phase and 1 M Na2S2O3 in the acceptor solution were established. The system offers enrichment factors of 1053 times, a limit of detection of 1.16 ng L-1. This method improves the limit of detection of the most recent liquid micro-extraction methods for silver pre-concentration coupled with GFAAS, being in this case comparable to ICP-MS detection based techniques.
Ämnesord
- NATURVETENSKAP -- Kemi (hsv//swe)
- NATURAL SCIENCES -- Chemical Sciences (hsv//eng)
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek