SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:4cf88eed-6d57-4a06-8826-e7c09737b8f3"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:4cf88eed-6d57-4a06-8826-e7c09737b8f3" > Scatter and attenua...

Scatter and attenuation correction in SPECT using density maps and Monte Carlo simulated scatter functions

Ljungberg, Michael (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Strand, Sven-Erik (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
 (creator_code:org_t)
1990
1990
Engelska.
Ingår i: Journal of Nuclear Medicine. - 0161-5505. ; 31:9, s. 1560-1567
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A new scatter and attenuation correction method is presented in which Monte Carlo simulated scatter line-spread functions for different depth and lateral positions are used. A reconstructed emission image is used as an estimate of the source distribution in order to calculate the scatter contribution in the projection data. The scatter contribution is then subtracted from the original projection prior to attenuation correction. The attenuation correction method uses density maps for the attenuation correction of projection data. Simulation studies have been done with a clinically realistic source distribution in cylindrical, homogeneous water phantoms of different sizes and with photon energies corresponding to 201T1, 99mTc, and 111In. The results show excellent quantitative results with an accuracy within +/- 10% for most of the source positions and phantom sizes. It has also been shown that the variation in the event distribution within the source region in the images has been significantly decreased and that an enhancement in the contrast has been achieved.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Ljungberg, Micha ...
Strand, Sven-Eri ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Journal of Nucle ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy