New non-invasive method for intima-media thickness and intima-media compression measurements

Cinthio, Magnus (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
Jansson, Tomas (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
Persson, Hans W (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
visa fler...
Lindström, Kjell (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
Rydén Ahlgren, Åsa (författare)
Lund University,Lunds universitet,Klinisk fysiologi och nuklearmedicin, Malmö,Forskargrupper vid Lunds universitet,Clinical Physiology and Nuclear Medicine, Malmö,Lund University Research Groups
visa färre...
 (creator_code:org_t)
2005
2005
Engelska.
Ingår i: Proceedings - IEEE Ultrasonics Symposium. - 1051-0117. - 0780393821 ; 1, s. 389-392
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • Intim a-media thickness (IMT) is considered as a valuable marker of early atherosclerosis. We suggest a new algorithm for simultaneous measurements of absolute diameter at diastole, distension (diameter change), IMT at diastole and the intima-media compression (IMC) with a new fast, robust, high-resolution, and automatic algorithm utilizing the ultrasonic gray-scale information. The new algorithm is evaluated in a limited in vivo study on the common carotid artery of 5 healthy volunteers. The standard deviation within an investigation was (8 ± 4 μm; range 4-14 μm) during IMC measurements, (8 ± 5 μm; range 4-16 μm) during the measurements of the IMT at diastole, (30 ±36 μm; range 6-92 μm) during the distension measurements and (48 ±49 μm; range 15-134 μm) during the measurements of the lumen diameter at diastole. The evaluation shows that the algorithm is fast and that the reproducibility and resolution are more than sufficient for in vivo studies. © 2005 IEEE.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Lumen diameter
Common carotid artery
Intima media thickness (IMT)
Intima media compression (IMC)

Publikations- och innehållstyp

kon (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy