SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:4ec3f5ba-9dfb-4cf6-9d9d-d2f5ef8608d3"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:4ec3f5ba-9dfb-4cf6-9d9d-d2f5ef8608d3" > A Case of Pacemaker...

A Case of Pacemaker Endocarditis Caused by Aerococcus urinae

Samuelsson, Sandra (författare)
Halmstad County Hospital
Kennergren, Charles (författare)
Sahlgrenska University Hospital
Rasmussen, Magnus (författare)
Lund University,Lunds universitet,Infektionsmedicin,Sektion III,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Translationell infektionsmedicin,Forskargrupper vid Lunds universitet,Infection Medicine (BMC),Section III,Department of Clinical Sciences, Lund,Faculty of Medicine,Translational infection medicine,Lund University Research Groups
 (creator_code:org_t)
Hindawi Limited, 2018
2018
Engelska.
Ingår i: Case Reports in Infectious Diseases. - : Hindawi Limited. - 2090-6625 .- 2090-6633. ; 2018
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: Aerococcus urinae has lately been acknowledged as a cause of infective endocarditis (IE) especially in older males with underlying urinary tract disorders. In this population, cardiac implanted electronical devices (CIED) are not uncommon, but despite the capacity of A. urinae to form biofilm in vitro, no cases of aerococcal CIED infections have been reported to date.Case Presentation: An 84-year-old male with pacemaker was admitted with dysuria one month after a transurethral procedure for urinary bladder cancer. A. urinae was isolated from urine and blood. Transesophageal echocardiography (TEE) was without signs of vegetation on valves or pacing cables. The patient was treated with a twelve-day course of β-lactam antibiotics. Forty days after the initial admission, the patient was readmitted due to malaise, general pain of the joints, chills, and renewed blood cultures grew A. urinae. TEE demonstrated a 10 × 5 mm vegetation on either the tricuspid valve or one of the pacing cables. The pacemaker system was completely removed and demonstrated macroscopic signs of infection. A temporary system was implanted, and after 14 days of penicillin G treatment, a new system permanent system was implanted. Total treatment time was 40 days. Recovery was uneventful.Conclusion: This report demonstrates that A. urinae can cause CIED infection. In patients with A. urinae bacteremia and a CIED, this risk must be considered, especially if bacteremia reoccurs.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Infektionsmedicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Infectious Medicine (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Urologi och njurmedicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Urology and Nephrology (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Samuelsson, Sand ...
Kennergren, Char ...
Rasmussen, Magnu ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Infektionsmedici ...
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Urologi och njur ...
Artiklar i publikationen
Case Reports in ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy