SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:53fadeca-99d7-4ee7-b62a-1589b56a5bf4"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:53fadeca-99d7-4ee7-b62a-1589b56a5bf4" > Analytical performa...

Analytical performance of aPROMISE : automated anatomic contextualization, detection, and quantification of [18F]DCFPyL (PSMA) imaging for standardized reporting

Johnsson, Kerstin (författare)
EXINI Diagnostics AB
Brynolfsson, Johan (författare)
EXINI Diagnostics AB
Sahlstedt, Hannicka (författare)
EXINI Diagnostics AB
visa fler...
Nickols, Nicholas G. (författare)
University of California, Los Angeles
Rettig, Matthew (författare)
VA Greater Los Angeles Healthcare System,University of California, Los Angeles
Probst, Stephan (författare)
Jewish General Hospital
Morris, Michael J. (författare)
Weill Cornell Medical College,Memorial Sloan-Kettering Cancer Center
Bjartell, Anders (författare)
Lund University,Lunds universitet,Urologisk cancerforskning, Malmö,Forskargrupper vid Lunds universitet,LUCC: Lunds universitets cancercentrum,Övriga starka forskningsmiljöer,Urological cancer, Malmö,Lund University Research Groups,LUCC: Lund University Cancer Centre,Other Strong Research Environments
Eiber, Mathias (författare)
Klinikum rechts der Isar
Anand, Aseem (författare)
Lund University,Lunds universitet,Urologisk cancerforskning, Malmö,Forskargrupper vid Lunds universitet,Urological cancer, Malmö,Lund University Research Groups,EXINI Diagnostics AB,Memorial Sloan-Kettering Cancer Center
visa färre...
 (creator_code:org_t)
2021-08-31
2022
Engelska.
Ingår i: European Journal of Nuclear Medicine and Molecular Imaging. - : Springer Science and Business Media LLC. - 1619-7070 .- 1619-7089. ; 49:3, s. 1041-1051
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose: The application of automated image analyses could improve and facilitate standardization and consistency of quantification in [18F]DCFPyL (PSMA) PET/CT scans. In the current study, we analytically validated aPROMISE, a software as a medical device that segments organs in low-dose CT images with deep learning, and subsequently detects and quantifies potential pathological lesions in PSMA PET/CT. Methods: To evaluate the deep learning algorithm, the automated segmentations of the low-dose CT component of PSMA PET/CT scans from 20 patients were compared to manual segmentations. Dice scores were used to quantify the similarities between the automated and manual segmentations. Next, the automated quantification of tracer uptake in the reference organs and detection and pre-segmentation of potential lesions were evaluated in 339 patients with prostate cancer, who were all enrolled in the phase II/III OSPREY study. Three nuclear medicine physicians performed the retrospective independent reads of OSPREY images with aPROMISE. Quantitative consistency was assessed by the pairwise Pearson correlations and standard deviation between the readers and aPROMISE. The sensitivity of detection and pre-segmentation of potential lesions was evaluated by determining the percent of manually selected abnormal lesions that were automatically detected by aPROMISE. Results: The Dice scores for bone segmentations ranged from 0.88 to 0.95. The Dice scores of the PSMA PET/CT reference organs, thoracic aorta and liver, were 0.89 and 0.97, respectively. Dice scores of other visceral organs, including prostate, were observed to be above 0.79. The Pearson correlation for blood pool reference was higher between any manual reader and aPROMISE, than between any pair of manual readers. The standard deviations of reference organ uptake across all patients as determined by aPROMISE (SD = 0.21 blood pool and SD = 1.16 liver) were lower compared to those of the manual readers. Finally, the sensitivity of aPROMISE detection and pre-segmentation was 91.5% for regional lymph nodes, 90.6% for all lymph nodes, and 86.7% for bone in metastatic patients. Conclusion: In this analytical study, we demonstrated the segmentation accuracy of the deep learning algorithm, the consistency in quantitative assessment across multiple readers, and the high sensitivity in detecting potential lesions. The study provides a foundational framework for clinical evaluation of aPROMISE in standardized reporting of PSMA PET/CT.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

aPROMISE
PSMA PET/CT evaluation
Segmentation
Standardized reporting

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy