SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:549242f6-980c-4f9a-8d91-007cb2f49e0a"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:549242f6-980c-4f9a-8d91-007cb2f49e0a" > Investigation of th...

Investigation of the effect of different glassy carbon materials on the performance of Prussian blue based sensors for hydrogen peroxide

Ricci, F (författare)
Palleschi, G (författare)
Yigzaw, Yirgalem (författare)
Lund University,Lunds universitet,Centrum för analys och syntes,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Centre for Analysis and Synthesis,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
visa fler...
Gorton, Lo (författare)
Lund University,Lunds universitet,Centrum för analys och syntes,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Centre for Analysis and Synthesis,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
Ruzgas, Tautgirdas (författare)
Lund University,Lunds universitet,Centrum för analys och syntes,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Centre for Analysis and Synthesis,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
Karyakin, A (författare)
visa färre...
 (creator_code:org_t)
Wiley, 2003
2003
Engelska.
Ingår i: Electroanalysis. - : Wiley. - 1040-0397 .- 1521-4109. ; 15:3, s. 175-182
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Three different kinds of glassy carbon (GC-R, GC-K, GC-G) were equally pretreated, further modified with electrochemically deposited Prussian Blue and used as sensors for hydrogen peroxide at an applied potential of -50 mV (vs. Ag|AgCl). Their performance was evaluated with respect to the following parameters: the coverage and electrochemistry of the electrodeposited Prussian Blue, the sensitivity and the lower limit of detection for hydrogen peroxide, and the operational stability of the sensors. GC-R showed the best behavior concerning the surface coverage and the operational stability of the electrodeposited Prussian Blue. For this electrode the sensitivity for hydrogen peroxide (10 M) was 0.25 A/M cm2 and the detection limit was 0.1 M. Scanning electron microscopy was used to study the surfaces of the three electrodes before and after the electrodeposition of Prussian Blue and to search for the reason for the three different behaviors between the different glassy carbon materials. The Prussian Blue modified GC-R was also used for the construction of a glucose biosensor based on immobilizing glucose oxidase in Nafion membranes on top of electrodeposited Prussian Blue layer. The operational stability of the glucose biosensors was studied in the flow injection mode at an applied potential of -50 mV (vs. Ag|AgCl) and alternatively injecting standard solutions of hydrogen peroxide (10 M) and glucose (1 mM) for 3 h. For the GC-R based biosensor a 2.8% decrease of the initial glucose response was observed.

Ämnesord

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Ricci, F
Palleschi, G
Yigzaw, Yirgalem
Gorton, Lo
Ruzgas, Tautgird ...
Karyakin, A
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Kemi
och Analytisk kemi
Artiklar i publikationen
Electroanalysis
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy