SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:54ddf3d9-53d2-4d51-9e75-2af0ca0a783b"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:54ddf3d9-53d2-4d51-9e75-2af0ca0a783b" > A fast analysis sys...

A fast analysis system for forensic DNA reference samples

Hedman, Johannes (författare)
Lund University,Lunds universitet,Teknisk mikrobiologi,Centrum för tillämpade biovetenskaper,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Applied Microbiology,Center for Applied Life Sciences,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
Albinsson, Linda (författare)
Ansell, Carina (författare)
visa fler...
Tapper, Helene (författare)
Hansson, Oskar (författare)
Holgersson, Stig (författare)
Ansell, Ricky, 1967- (författare)
Linköpings universitet,Molekylär genetik,Hälsouniversitetet
visa färre...
 (creator_code:org_t)
Elsevier BV, 2008
2008
Engelska.
Ingår i: Forensic Science International: Genetics. - : Elsevier BV. - 1878-0326 .- 1872-4973. ; 2:3, s. 184-189
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • On January 1st, 2006, the Swedish legislation on obtaining DNA reference samples from Suspects and the recording of DNA profiles in databases was changed. As a result the number of samples analysed at the Swedish National Laboratory of Forensic Science (SKL) increased from about 4500 in 2005 to more than 25,000 in 2006. To meet this challenge, SKL launched a flew analysis system to create an unbroken chain, from sampling to incorporation of a profile in the national DNA database and subsequent automatic generation of digitally signed hit reports. The system integrates logistics, digital data transfer, new functions in LIMS (ForumDNA Version 4, Ida Infront AB) and laboratory automation. Buccal swab samples are secured on a FTA (R) card attached to an identity form, which is barcoded with a unique sample ID. After sampling, the police officer sends a digital request to SKL. The sample is automatically registered in LIMS and processed on delivery. The resulting DNA profiles are automatically classified according to quality using a custom-made expert system. Building the evaluation around mathematical rules makes it reproducible, standardised and minimises manual work and clerk errors. All samples are run in duplicate and the two profiles are compared within LIMS before incorporation in the database. In the first year of operation, the median time for completion of an analysis was 3 days, measured from delivery of the sample to incorporation of the profile in the national DNA database. In spite of the dramatic increase in the number of reference samples there was no backlog. (C) 2008 Elsevier Ireland Ltd. All rights reserved.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Industriell bioteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Industrial Biotechnology (hsv//eng)

Nyckelord

DNA database
Forensic DNA analysis
Reference sample
Automation
LIMS
NATURAL SCIENCES

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy