SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:5780e2d9-5bff-4cc8-89f7-d065f2d411e8"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:5780e2d9-5bff-4cc8-89f7-d065f2d411e8" > Performance Evaluat...

Performance Evaluation of a High Solar Fraction CPC-Collector System

Bernardo, Ricardo (författare)
Lund University,Lunds universitet,Institutionen för arkitektur och byggd miljö,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Architecture and Built Environment,Departments at LTH,Faculty of Engineering, LTH
Davidsson, Henrik (författare)
Lund University,Lunds universitet,Institutionen för arkitektur och byggd miljö,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Architecture and Built Environment,Departments at LTH,Faculty of Engineering, LTH
Karlsson, Björn (författare)
Lund University,Lunds universitet,Avdelningen för Energi och byggnadsdesign,Institutionen för bygg- och miljöteknologi,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Energy and Building Design,Department of Building and Environmental Technology,Departments at LTH,Faculty of Engineering, LTH
 (creator_code:org_t)
Japan Society of Mechanical Engineers, 2011
2011
Engelska.
Ingår i: Journal of Environment and Engineering. - : Japan Society of Mechanical Engineers. - 1880-988X. ; 6:3, s. 680-692
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • One of the most important goals on solar collector development is to increase the system’s annual performance without increasing overproduction. The studied collector is formed by a compound parabolic reflector which decreases the collector optical efficiency during the summer period. Hence, it is possible to increase the collector area and thus, the annual solar fraction, without increasing the overproduction. Collector measurements were fed into a validated TRNSYS collector model which estimates the solar fraction of the concentrating system and also that of a traditional flat plate collector, both for domestic hot water production. The system design approach aims to maximise the collector area until an annual overproduction limit is reached. This is defined by a new deterioration factor that takes into account the hours and the collector temperature during stagnation periods. Then, the highest solar fraction achieved by both systems was determined. The results show that, at 50° tilt in Lund, Sweden, the concentrating system achieves 71% solar fraction using 17 m2 of collector area compared to 66% solar fraction and 7 m2 of a flat plate collector system. Thus, it is possible to install 2.4 times more collector area and achieve a higher solar fraction using the load adapted collector. However, the summer optical efficiency reduction was proven to be too abrupt. If the reflector geometry is properly design, the load adapted collector can be a competitive solution in the market if produced in an economical way.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering (hsv//eng)

Nyckelord

Concentrating Solar Thermal
CPC
Domestic Hot Water
High Solar Fraction

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Bernardo, Ricard ...
Davidsson, Henri ...
Karlsson, Björn
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Samhällsbyggnads ...
Artiklar i publikationen
Journal of Envir ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy