Sökning: id:"swepub:oai:lup.lub.lu.se:57ae335c-9ecd-4754-9eec-ddc7b82669cf" >
Central and mixed v...
Central and mixed venous blood oxygen correlate well during acute normovolemic hemodilution in anesthetized pigs
-
- Schou, Henning (författare)
- Lund University,Lunds universitet,Anestesiologi och intensivvård,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Anesthesiology and Intensive Care,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
-
- Perez de Sá, Valéria (författare)
- Lund University,Lunds universitet,Anestesiologi och intensivvård,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Anesthesiology and Intensive Care,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
-
Larsson, A (författare)
-
(creator_code:org_t)
- 1998
- 1998
- Engelska.
-
Ingår i: Acta Anaesthesiologica Scandinavica. - 0001-5172. ; 42:2, s. 172-177
- Relaterad länk:
-
https://lup.lub.lu.s...
Abstract
Ämnesord
Stäng
- BACKGROUND: Central venous oxygen saturation (ScvO2) and oxygen tension (PcvO2), obtained from the superior vena cava, correlate well with mixed venous (pulmonary arterial) oxygen saturation (SvO2) and tension (pvO2) when the hematocrit is normal. The present study was undertaken to assess whether extreme hemodilution affects this relation. METHODS: We compared mixed and central venous blood during graded arterial desaturation (inspired fraction of oxygen (FIO2) between 1.0 and 0.10) in 10 hemodiluted pigs, and in 10 pigs with normal hematocrit (control), during fentanyl-ketamine-pancuronium anesthesia and mechanical ventilation. RESULTS: Arterial oxygen saturation decreased from 100% at FIO2 = 1.0 to 44 +/- 12% at FIO2 = 0.10 (mean +/- SD). Venous oxygen saturation ranged from 3.5% to 97.3%. The regression coefficient between SvO2 and ScvO2 was 0.97 (R2 = 0.93, bias -2.4 +/- 5.8%) in the hemodiluted and 0.99 (R2 = 0.97, bias -3.0 +/- 5.0%) in the control group. Venous oxygen tension values ranged from 0.5 kPa to 9.5 kPa, and the regression coefficient for oxygen tension was 0.94 (R2 = 0.89, bias -0.20 +/- 0.47 kPa) in the hemodiluted and 0.99 (R2 = 0.97, bias -0.43 +/- 0.48 kPa) in the control group. The regression coefficient for pH was 0.95 in the hemodiluted and 0.98 in the control animals. CONCLUSION: The findings indicate that also during hemodilution monitoring of central venous blood oxygen may be as useful as monitoring of mixed venous blood oxygen.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Anestesi och intensivvård (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Anesthesiology and Intensive Care (hsv//eng)