SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:59357481-e0ac-42ef-b1c8-f832ebf83961"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:59357481-e0ac-42ef-b1c8-f832ebf83961" > Interference elimin...

Interference elimination in glutamate monitoring with chip integrated enzyme microreactors

Collins, A. (författare)
Mikeladze, E. (författare)
Bengtsson, M. (författare)
visa fler...
Kokaia, M. (författare)
Laurell, Thomas (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
Csöregi, Elisabeth (författare)
Lund University,Lunds universitet,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
visa färre...
 (creator_code:org_t)
2001
2001
Engelska.
Ingår i: Electroanalysis. - 1040-0397. ; 13:6, s. 425-431
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • On-chip enzyme reactors are often used in medical/pharmaceutical analysis due to their inherent advantages, such as high sample throughput, low reagent consumption, stability, reproducibility and low cost. The present work describes a different application of such microreactors, namely, elimination of interfering ascorbate signals in glutamate monitoring using ascorbate oxidase modified silicon chip microreactors of different sizes (5.3 and 0.95 muL). Glutamate was monitored with a previously developed redox hydrogel integrated bienzyme electrode, based on coupled glutamate oxidase and horseradish peroxidase, inserted in a miniaturized flow cell operated at -50 mV (vs. Ag/AgCl). The developed on-line analysis system was characterized with regard to dilution effects, detection limit, response time and interference ability using model solutions and real samples. Off-line in vivo glutamate measurements could be made by injecting rat brain microdialysate samples collected before and after KCl stimulation without any interference of ascorbate, I Within the studied flow rate range (2-25 muL/min), 1 mM and 200 muM ascorbate could he totally eliminated using the larger and the mailer microreactor, respectively.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Industriell bioteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Industrial Biotechnology (hsv//eng)

Nyckelord

glutamate
amperometric biosensor
ascorbate interference elimination
immobilized enzyme reactors
FLOW-INJECTION-ANALYSIS
POROUS SILICON
AMPEROMETRIC DETERMINATION
EXTRACELLULAR GLUTAMATE
GLUCOSE SENSOR
BIOSENSOR
OXIDASE
ELECTRODE
REACTORS
DEHYDROGENASE

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Collins, A.
Mikeladze, E.
Bengtsson, M.
Kokaia, M.
Laurell, Thomas
Csöregi, Elisabe ...
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Industriell biot ...
Artiklar i publikationen
Electroanalysis
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy