Immobilised activated sludge based biosensor for biochemical oxygen demand measurement

Liu, Jing (författare)
Lund University,Lunds universitet,Bioteknik,Centrum för tillämpade biovetenskaper,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Biotechnology,Center for Applied Life Sciences,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
Björnsson, Lovisa (författare)
Lund University,Lunds universitet,Miljö- och energisystem,Institutionen för teknik och samhälle,Institutioner vid LTH,Lunds Tekniska Högskola,Environmental and Energy Systems Studies,Department of Technology and Society,Departments at LTH,Faculty of Engineering, LTH
Mattiasson, Bo (författare)
Lund University,Lunds universitet,Bioteknik,Centrum för tillämpade biovetenskaper,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Biotechnology,Center for Applied Life Sciences,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
 (creator_code:org_t)
2000
2000
Engelska.
Ingår i: Biosensors & Bioelectronics. - 1873-4235. ; 14:12, s. 883-893
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A biochemical oxygen demand (BOD) sensor, based on an immobilised mixed culture of microorganisms in combination with a dissolved oxygen electrode, has been developed for the purpose of on-line monitoring of the biological treatment process for waste and wastewater. The sensor was designed for easy replacement of the biomembrane, thereby making it suitable for short-term use. The drawbacks of activated sludge based sensor, such as short sensor lifetime, were thereby circumvented. The sensor BOD measurements were carried out in the kinetic mode using a flow injection system, resulting in 25 s for one measurement followed by 4-8 min recovery time. Based on the results of normalised sensor responses, the OECD synthetic wastewater was considered to be a more suitable calibration solution in comparison with the GGA solution. Good agreement was achieved between the results of the sensor BOD measurement and those obtained from BOD5 analysis of a wastewater sample from a food-processing factory. Reproducibility of responses using one sensor was below +/-5.6% standard deviation. Reproducibility of responses using different sensors was within acceptable bias limits, viz. +/-15% standard deviation.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Industriell bioteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Industrial Biotechnology (hsv//eng)

Nyckelord

Biochemical oxygen demand
Activated sludge
Microbial consortium
Kinetic mode
Dynamic mode
Wastewater
BOD sensor

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Liu, Jing
Björnsson, Lovis ...
Mattiasson, Bo
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Industriell biot ...
Artiklar i publikationen
Biosensors & Bio ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy