Sökning: id:"swepub:oai:lup.lub.lu.se:5db7c93e-1c57-4cc2-a5d9-6ec87a6df5d6" >
False-positive reca...
False-positive recalls in the prospective Malmö Breast Tomosynthesis Screening Trial
-
- Johnson, Kristin (författare)
- Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,LUCC: Lunds universitets cancercentrum,Övriga starka forskningsmiljöer,Radiology Diagnostics, Malmö,Lund University Research Groups,LUCC: Lund University Cancer Centre,Other Strong Research Environments,Skåne University Hospital
-
- Olinder, Jakob (författare)
- Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,LUCC: Lunds universitets cancercentrum,Övriga starka forskningsmiljöer,Radiology Diagnostics, Malmö,Lund University Research Groups,LUCC: Lund University Cancer Centre,Other Strong Research Environments,Skåne University Hospital
-
- Rosso, Aldana (författare)
- Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,Geriatrik,LUCC: Lunds universitets cancercentrum,Övriga starka forskningsmiljöer,Radiology Diagnostics, Malmö,Lund University Research Groups,Geriatrics,LUCC: Lund University Cancer Centre,Other Strong Research Environments,Skåne University Hospital
-
visa fler...
-
- Andersson, Ingvar (författare)
- Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,LUCC: Lunds universitets cancercentrum,Övriga starka forskningsmiljöer,Radiology Diagnostics, Malmö,Lund University Research Groups,LUCC: Lund University Cancer Centre,Other Strong Research Environments,Skåne University Hospital
-
- Lång, Kristina (författare)
- Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,LUCC: Lunds universitets cancercentrum,Övriga starka forskningsmiljöer,Radiology Diagnostics, Malmö,Lund University Research Groups,LUCC: Lund University Cancer Centre,Other Strong Research Environments,Skåne University Hospital
-
- Zackrisson, Sophia (författare)
- Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,LUCC: Lunds universitets cancercentrum,Övriga starka forskningsmiljöer,LTH profilområde: Avancerade ljuskällor,LTH profilområden,Lunds Tekniska Högskola,LU profilområde: Ljus och material,Lunds universitets profilområden,Radiology Diagnostics, Malmö,Lund University Research Groups,LUCC: Lund University Cancer Centre,Other Strong Research Environments,LTH Profile Area: Photon Science and Technology,LTH Profile areas,Faculty of Engineering, LTH,LU Profile Area: Light and Materials,Lund University Profile areas,Skåne University Hospital
-
visa färre...
-
(creator_code:org_t)
- 2023
- 2023
- Engelska 12 s.
-
Ingår i: European Radiology. - 0938-7994. ; 33:11, s. 8089-8099
- Relaterad länk:
-
http://dx.doi.org/10... (free)
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Objectives: To evaluate the total number of false-positive recalls, including radiographic appearances and false-positive biopsies, in the Malmö Breast Tomosynthesis Screening Trial (MBTST). Methods: The prospective, population-based MBTST, with 14,848 participating women, was designed to compare one-view digital breast tomosynthesis (DBT) to two-view digital mammography (DM) in breast cancer screening. False-positive recall rates, radiographic appearances, and biopsy rates were analyzed. Comparisons were made between DBT, DM, and DBT + DM, both in total and in trial year 1 compared to trial years 2 to 5, with numbers, percentages, and 95% confidence intervals (CI). Results: The false-positive recall rate was higher with DBT, 1.6% (95% CI 1.4; 1.8), compared to screening with DM, 0.8% (95% CI 0.7; 1.0). The proportion of the radiographic appearance of stellate distortion was 37.3% (91/244) with DBT, compared to 24.0% (29/121) with DM. The false-positive recall rate with DBT during trial year 1 was 2.6% (95% CI 1.8; 3.5), then stabilized at 1.5% (95% CI 1.3; 1.8) during trial years 2 to 5. The percentage of stellate distortion with DBT was 50% (19/38) trial year 1 compared to 35.0% (72/206) trial years 2 to 5. Conclusions: The higher false-positive recall rate with DBT compared to DM was mainly due to an increased detection of stellate findings. The proportion of these findings, as well as the DBT false-positive recall rate, was reduced after the first trial year. Clinical relevance statement: Assessment of false-positive recalls gives information on potential benefits and side effects in DBT screening. Key Points: • The false-positive recall rate in a prospective digital breast tomosynthesis screening trial was higher compared to digital mammography, but still low compared to other trials. • The higher false-positive recall rate with digital breast tomosynthesis was mainly due to an increased detection of stellate findings; the proportion of these findings was reduced after the first trial year.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Cancer och onkologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Cancer and Oncology (hsv//eng)
Nyckelord
- Breast neoplasm
- Female
- Mammography
- Mass screening
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas