Comparison of measured and calculated temperature and relative humidity with varied and constant air flow in the facade air gap

Mundt Petersen, Solof (author)
Lund University,Lunds universitet,Avdelningen för Byggnadsfysik,Institutionen för bygg- och miljöteknologi,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Building Physics,Department of Building and Environmental Technology,Departments at LTH,Faculty of Engineering, LTH
Harderup, Lars-Erik (author)
Lund University,Lunds universitet,Avdelningen för Byggnadsfysik,Institutionen för bygg- och miljöteknologi,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Building Physics,Department of Building and Environmental Technology,Departments at LTH,Faculty of Engineering, LTH
Vinha, Juha (editor)
show more...
Piironen, Jarkko (editor)
Salminen, Kati (editor)
show less...
 (creator_code:org_t)
2011
2011
English 8 s.
In: Proceedings of the 9th Nordic Symposium on Building Physics - NSB 2011. - 9789521525742 ; 1, s. 147-154
  • Conference paper (peer-reviewed)
Abstract Subject headings
Close  
  • Calculation of relative humidity and temperature in an early stage of the design process is important to avoid moisture damages in wooden walls. Previous studies show that a sufficient air flow in the air gap behind the façade panel is important to ensure a moisture safe construction. This study investigates if blind WUFI 5.0 calculations with a varied air flow in the air gap behind the façade give a better correlation to measured values compared to calculations with a constant air flow. Calculations for two cases are compared to measured values in single family house. The results show that calculations with a wind dependent air flow does not necessary give better correlation to measured values compared to calculations with a constant air flow. However, the calculated values are confirmed with measured values during the warm period and there are deviations in the outer part of the wall during the cold period. Variations in measured values at the same depth in different places in the studied wall are larger compared to differences between calculated values with or without a wind dependent air flow in the façade air gap.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Husbyggnad (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Building Technologies (hsv//eng)

Keyword

Comparison
measurements
moisture
WUFI 5.0
calculations mould

Publication and Content Type

kon (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Find more in SwePub

By the author/editor
Mundt Petersen, ...
Harderup, Lars-E ...
Vinha, Juha
Piironen, Jarkko
Salminen, Kati
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Civil Engineerin ...
and Building Technol ...
Articles in the publication
Proceedings of t ...
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view