SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:68aaf102-04f9-4b81-af94-9d5d99469077"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:68aaf102-04f9-4b81-af94-9d5d99469077" > Fat quantification ...

Fat quantification using multiecho sequences with bipolar gradients: Investigation of accuracy and noise performance.

Peterson, Pernilla (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
Månsson, Sven (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
 (creator_code:org_t)
2013-02-14
2014
Engelska.
Ingår i: Magnetic Resonance in Medicine. - : Wiley. - 1522-2594 .- 0740-3194. ; 71:1, s. 219-229
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • PURPOSE: To investigate the accuracy and noise performance of fat quantification with multiple gradient-echo images acquired using bipolar read-out gradients and compare them with those of the well-established unipolar technique. THEORY: The bipolar read-out technique induces phase and amplitude errors caused by gradient delays, eddy currents, and frequency-dependent coil sensitivity. In this study, these errors were corrected for jointly with the fat/water separation by modeling the impact of these effects on the signal. This approach did not require acquisition of reference data or modification of the pulse sequence. METHODS: Simulations and a phantom experiment were used to investigate the accuracy and noise performance of the technique and compare them with those of a well-established technique using unipolar read-out gradients. Also, the in vivo feasibility was demonstrated for abdominal applications. RESULTS: The phantom experiment demonstrated similar accuracy of the bipolar and unipolar fat quantification techniques. In addition, the noise performance was shown not to be affected by the added estimations of the phase and amplitude errors for most inter-echo times. CONCLUSION: The bipolar technique was found to provide accurate fat quantification with noise performance similar to the unipolar technique given an appropriate choice of inter-echo time. Magn Reson Med, 2013. © 2013 Wiley Periodicals, Inc.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Peterson, Pernil ...
Månsson, Sven
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Magnetic Resonan ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy