SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:6b696448-0041-48ef-8695-74c71675414d"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:6b696448-0041-48ef-8695-74c71675414d" > Simultaneous mappin...

Simultaneous mapping of T1and B1+ in human brain at 7T

Olsson, Hampus (författare)
Lund University,Lunds universitet,MR Physics,Forskargrupper vid Lunds universitet,Lund University Research Groups
Andersen, Mads (författare)
Lund University,Lunds universitet,Lund University Bioimaging Center,Medicinska fakulteten,Faculty of Medicine,Philips Healthcare, Denmark
Kadhim, Mustafa (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
visa fler...
Helms, Gunther (författare)
Lund University,Lunds universitet,MR Physics,Forskargrupper vid Lunds universitet,Lund University Research Groups
visa färre...
 (creator_code:org_t)
2022-01-17
2022
Engelska.
Ingår i: Magnetic Resonance in Medicine. - : Wiley. - 1522-2594 .- 0740-3194. ; 87:6, s. 2637-2649
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • PurposeTo map T1 and the local flip angle (B1+) in human brain using a single MP3RAGE sequence with 3 rapid acquisitions of gradient echoes (RAGEs).Theory and methodsA third RAGE with a relatively high flip angle was appended to an MP2RAGE sequence. Through curve fitting and a rational approximation for small flip angles and short TR, closed form solutions for T1 and B1+ were derived. The influence of different k-space encoding schemes on precision and whether edge enhancement artifacts could be reduced with a saturation pulse applied prior to the third RAGE were explored. Validation of T1 estimates was performed using single-slice inversion recovery (IR) and a subsequent region-of-interest–based comparison, whereas validation of B1+ was performed using a whole brain pixelwise comparison to a DREAM flip angle mapping protocol. Lastly, MP3RAGE was compared to T1-mapping by MP2RAGE with separate B1+ correction.ResultsWhole brain maps of T1 and B1+ at 1 mm isotropic resolution were obtained with MP3RAGE in 06:37 min. A linear–reverse centric–reverse centric phase-encoding order of the 3 RAGEs improved precision, and artifacts were successfully reduced with the saturation pulse. Estimations of T1 and B1+ deviated +2.5 ± 3.1% and −1.7 ± 8.6% from their respective references.ConclusionT1 and B1+ can be mapped simultaneously using MP3RAGE. The approach can be thought of as combining MP2RAGE with a dual flip angle T1-mapping protocol. Both maps can be solved for analytically and will be inherently co-registered at the high resolution associated with MPRAGE.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
NATURVETENSKAP  -- Fysik -- Annan fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Other Physics Topics (hsv//eng)

Nyckelord

7T, B1+ mapping, dual flip angle, MPRAGE, T1- mapping

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Olsson, Hampus
Andersen, Mads
Kadhim, Mustafa
Helms, Gunther
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
NATURVETENSKAP
NATURVETENSKAP
och Fysik
och Annan fysik
Artiklar i publikationen
Magnetic Resonan ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy