Effects of Inflow and Radiofrequency Spoiling on the Arterial Input Function in Dynamic Contrast-Enhanced MRI: A Combined Phantom and Simulation Study

Garpebring, Anders (författare)
Umeå universitet,Radiofysik
Wirestam, Ronnie (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Östlund, Nils (författare)
Umeå universitet,Radiofysik
visa fler...
Karlsson, Mikael (författare)
Umeå universitet,Radiofysik
visa färre...
 (creator_code:org_t)
2011-02-08
2011
Engelska.
Ingår i: Magnetic Resonance in Medicine. - : Wiley. - 1522-2594 .- 0740-3194. ; 65:6, s. 1670-1679
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The arterial input function is crucial in pharmacokinetic analysis of dynamic contrast-enhanced MRI data. Among other artifacts in arterial input function quantification, the blood inflow effect and nonideal radiofrequency spoiling can induce large measurement errors with subsequent reduction of accuracy in the pharmacokinetic parameters. These errors were investigated for a 3D spoiled gradient-echo sequence using a pulsatile flow phantom and a total of 144 typical imaging settings. In the presence of large inflow effects, results showed poor average accuracy and large spread between imaging settings, when the standard spoiled gradient-echo signal equation was used in the analysis. For example, one of the investigated inflow conditions resulted in a mean error of about 40% and a spread, given by the coefficient of variation, of 20% for K-trans. Minimizing inflow effects by appropriate slice placement, combined with compensation for nonideal radiofrequency spoiling, significantly improved the results, but they remained poorer than without flow (e. g., 3-4 times larger coefficient of variation for K-trans). It was concluded that the 3D spoiled gradient-echo sequence is not optimal for accurate arterial input function quantification and that correction for nonideal radiofrequency spoiling in combination with inflow minimizing slice placement should be used to reduce the errors. Magn Reson Med 65:1670-1679, 2011. (C)2011 Wiley-Liss, Inc.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

dynamic contrast-enhanced MRI
arterial input function
blood flow
effects
RF spoiling
dynamic contrast-enhanced MRI

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy