Association between keratoconus disease severity and repeatability in measurements of parameters for the assessment of progressive disease

Gustafsson, Ingemar (författare)
Lund University,Lunds universitet,Klinisk forskning inom hornhinnesjukdomar,Forskargrupper vid Lunds universitet,Clinical research in corneal disease and disorders,Lund University Research Groups,Skåne University Hospital
Bergström, Anders (författare)
Lund University,Lunds universitet,Oftalmologi, Lund,Sektion IV,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Ophthalmology, Lund,Section IV,Department of Clinical Sciences, Lund,Faculty of Medicine,Skåne University Hospital
Myers, Anna Cardiakides (författare)
Lund University,Lunds universitet,Klinisk forskning inom hornhinnesjukdomar,Forskargrupper vid Lunds universitet,Clinical research in corneal disease and disorders,Lund University Research Groups
visa fler...
Ivarsen, Anders (författare)
Aarhus University Hospital
Hjortdal, Jesper (författare)
Aarhus University Hospital
visa färre...
 (creator_code:org_t)
2020-02-14
2020
Engelska.
Ingår i: PLoS ONE. - : Public Library of Science (PLoS). - 1932-6203. ; 15:2
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background Progressive keratoconus can lead to severely impaired vision, but there is currently no consensus on the definition of progressive disease. Errors in the measurement of the parameters commonly used to establish progressive disease were evaluated in an attempt to determine the limits at which a true change in the values can be detected. The possible association between measurement error and disease severity was also investigated to evaluate the need for limits based on disease severity. Methods Sixty-one eyes were studied in 61 patients with keratoconus. Four replicate measurements were made in each patient using a Scheimpflug-based tomographic system (denoted the PC) and an auto-keratometer (denoted the AK). The repeatability coefficient, i.e., the level below which differences between two measurements are found in 95% of paired observations, was calculated. Patients were further divided into three groups based on disease severity (parameter magnitude). Results Increasing magnitude of all the keratometric parameters investigated was significantly associated with increasing measurement errors, and thus worse repeatability. The maximum keratometry value (Kmax) was the least repeatable parameter (1.23 D, 95% CI 1.11–1.35 D) and showed the strongest association between parameter magnitude and measurement error. The repeatability coefficient ranged between 0.32 and 1.62 D, depending on disease severity. The most repeatable parameter was the flattest central keratometry value (K1), measured with the PC (0.51 D, 95% CI 0.46–0.56 D) and the AK (0.54 D, 95% CI 0.48–0.59 D). K1 showed the weakest association between parameter magnitude and measurement error. The repeatability coefficient for K1 ranged between 0.40 and 0.54 D when using the PC, and between 0.34 and 0.70 D when using the AK in the three groups. Conclusions The association between the magnitude of the keratometric parameters and their measurement errors suggests that limits should be based on disease severity to ensure reliable detection of progressive keratoconus. Further studies are, however, required.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Oftalmologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Ophthalmology (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

  • PLoS ONE (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Gustafsson, Inge ...
Bergström, Ander ...
Myers, Anna Card ...
Ivarsen, Anders
Hjortdal, Jesper
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Oftalmologi
Artiklar i publikationen
PLoS ONE
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy