SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:7333d106-f769-4071-a8bc-5506cf70b534"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:7333d106-f769-4071-a8bc-5506cf70b534" > On the biologically...

On the biologically effective dose (BED)-using convolution for calculating the effects of repair: II. Numerical considerations.

Gustafsson, Johan Ruben (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Nilsson, Per (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Sjögreen Gleisner, Katarina (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
 (creator_code:org_t)
2013-02-13
2013
Engelska.
Ingår i: Physics in Medicine and Biology. - : IOP Publishing. - 1361-6560 .- 0031-9155. ; 58:5, s. 1529-1548
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • We have previously shown analytically that the biologically effective dose (BED), including effects of repair during irradiation and of incomplete repair between fractions, can be formulated using a convolution between the absorbed dose rate function and the function describing repair. In this work, a discrete formalism is derived along with its implementation via the fast Fourier transform. The implementation takes the intrinsic periodicity of the discrete Fourier transform into consideration, as well as possible inconsistencies that may arise due to discretization and truncation of the functions describing the absorbed dose rate and repair. Numerically and analytically calculated BED values are compared for various situations in external beam radiotherapy, brachytherapy and radionuclide therapy, including the use of different repair models. The numerical method is shown to be accurate and versatile since it can be applied to any kind of absorbed dose rate function and allows for the incorporation of different repair models. Typical accuracies for clinically realistic examples are in the order of 10(-3)% to 10(-5)%. The method has thus the potential of being a useful tool for the calculation of BED, also in situations with complicated irradiation patterns or repair functions.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Gustafsson, Joha ...
Nilsson, Per
Sjögreen Gleisne ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Physics in Medic ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy