High sample throughput flow immunoassay utilising restricted access columns for the separation of bound and free label

Önnerfjord, Patrik (författare)
Lund University,Lunds universitet,Centrum för analys och syntes,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Centre for Analysis and Synthesis,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
Eremin, Sergei A. (författare)
Lomonosov Moscow State University
Emnéus, Jenny (författare)
Lund University,Lunds universitet,Centrum för analys och syntes,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Centre for Analysis and Synthesis,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
visa fler...
Marko-Varga, György (författare)
Astra Draco AB
visa färre...
 (creator_code:org_t)
1998
1998
Engelska.
Ingår i: Journal of Chromatography A. - 0021-9673. ; 800:2, s. 219-230
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A flow immunodetection system with high sample throughput capacity is described for the screening of various analytes. The immunochemical detection principle is based on the chromatographic separation of the formed immunocomplex (AbAg or AbAg*) and the free antigen (Ag) by a restricted access (RA) column, utilising size-exclusion and reversed-phase mechanism. A fluorescein labelled analyte (Ag*) was used in the competitive assay format with fluorescence detection. The speed and simplicity of the assay were the greatest advantages, allowing measurement of the analyte to be carried out in less than 1 min. The biocompatibility and capacity of the restricted access material allowed multiple injections of up to 5000, without any breakthrough of the fluorescent tracer molecule and thus need for regeneration. The flow immunoassay was developed using the well-known atrazine herbicide and some transformation products as model compounds, due to their human toxicity and widespread use. The sample throughput was 80 samples per hour and the detection limits were 1.4 nM (300 pg/ml) for atrazine (Ab I) and 2.3 nM (500 pg/ml) for the sum of triazines (Ab II-III). Different sample matrices, PBS buffer, creek water, and urine were successfully applied in the flow system without the need for any sample handling step. For plasma samples an additional clean-up step using solid-phase extraction had to be included. The resulting detection limits for atrazine in plasma and water samples using this clean-up and trace enrichment procedure were found to be 2 ng/ml and 20 pg/ml, respectively. The analysis could be performed at a sample throughput rate of 400 per 6-h working shift.

Ämnesord

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)

Nyckelord

Atrazine
Flow immunoassay
Pesticides
Restricted access column

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Önnerfjord, Patr ...
Eremin, Sergei A ...
Emnéus, Jenny
Marko-Varga, Gyö ...
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Kemi
och Analytisk kemi
Artiklar i publikationen
Journal of Chrom ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy