SwePub
Sök i LIBRIS databas

  Extended search

id:"swepub:oai:lup.lub.lu.se:745ff6ce-ef01-47c7-8f99-efb40c361918"
 

Search: id:"swepub:oai:lup.lub.lu.se:745ff6ce-ef01-47c7-8f99-efb40c361918" > Planar gamma scinti...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Planar gamma scintigraphy - points to consider when quantifying pulmonary dry powder aerosol deposition

Bondesson, Eva (author)
Lund University,Lunds universitet,Klinisk fysiologi och nuklearmedicin, Malmö,Forskargrupper vid Lunds universitet,Clinical Physiology and Nuclear Medicine, Malmö,Lund University Research Groups
Bengtsson, T (author)
Borgstrom, L (author)
show more...
Nilsson, L (author)
Norrgren, Kristina (author)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
Trofast, E (author)
Wollmer, Per (author)
Lund University,Lunds universitet,Klinisk fysiologi och nuklearmedicin, Malmö,Forskargrupper vid Lunds universitet,Clinical Physiology and Nuclear Medicine, Malmö,Lund University Research Groups
show less...
 (creator_code:org_t)
2003
2003
English.
In: International Journal of Pharmaceutics. - 1873-3476. ; 251:1-2, s. 33-47
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Methodological aspects of planar gamma scintigraphy used to quantify pulmonary aerosol deposition were investigated using an experimental dry powder formulation. Particles of micronized salbutamol sulphate were labelled with technetium-99m and admixed to an ordered mixture of unlabelled micronized salbutamol sulphate and larger carrier particles of lactose. The radioaerosol was administered to 24 healthy subjects, 12 in each of two consecutive, similarly designed studies. Pulmonary deposition was determined using two methods: repeated planar imaging, and pharmacokinetic assessments following charcoal co-administration to prevent gastrointestinal salbutamol absorption. After due consideration had been taken to ensure appropriate radiolabelling, image acquisition and processing procedures, a scintigraphic estimate of 26.2% (24.2-28.4%) was obtained, which did not significantly differ from the pharmacokinetic estimate of 26.4% (24.4-28.7%). In summary, pre-study validation of the radiolabelling technique, quality control of radioaerosols produced during the study, correction for re-distribution of radiolabel from the lungs, selection of regions of interest, assessment of lung contours, correction for tissue attenuation of gamma rays and establishment of the actual recovery of radioactivity in the scintigraphic measurements could potentially affect the accuracy of the scintigraphic estimate of pulmonary deposition and, thus, should be carefully considered in the design or evaluation of any such study.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Keyword

inhalation
administration
radionuclide imaging
radioactive aerosol
technetium-99m
powder inhaler

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view