SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:749f67ae-0e84-4962-a03e-89d652b6e3ff"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:749f67ae-0e84-4962-a03e-89d652b6e3ff" > An experimental inv...

An experimental investigation on the thermal augmentation of internal endwall in a two-pass duct using an array of delta-winglet vortex generator pair

Luo, Lei (författare)
Harbin Institute of Technology
Zhao, Zhiqi (författare)
Harbin Institute of Technology
Qiu, Dandan (författare)
Harbin Institute of Technology
visa fler...
Wang, Songtao (författare)
Harbin Institute of Technology
Wang, Zhongqi (författare)
Harbin Institute of Technology
Sundén, Bengt (författare)
Lund University,Lunds universitet,Värmeöverföring,Institutionen för energivetenskaper,Institutioner vid LTH,Lunds Tekniska Högskola,LTH profilområde: Nanovetenskap och halvledarteknologi,LTH profilområden,Heat Transfer,Department of Energy Sciences,Departments at LTH,Faculty of Engineering, LTH,LTH Profile Area: Nanoscience and Semiconductor Technology,LTH Profile areas,Faculty of Engineering, LTH
visa färre...
 (creator_code:org_t)
Elsevier BV, 2022
2022
Engelska.
Ingår i: International Journal of Heat and Mass Transfer. - : Elsevier BV. - 0017-9310. ; 182
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The present study experimentally demonstrates a novel design for an internal endwall in a two-pass duct heat exchanger. An array of delta-winglet vortex generator pairs with different aspect ratio, angle of attack, configuration are mounted on the internal endwall in a U duct. Liquid crystal thermalgraphy and static pressure measurements are utilized in this study to evaluate the heat transfer, thermal-hydraulic performance, and pressure drop penalty. The Reynolds number is varied from 10,000 to 20,000. A comparison between the current novel design and traditional enhanced heat transfer turbulators in the open literature is also included. The results show that the endwall heat transfer is enhanced greatly as the longitudinal vortex generator array is located on the endwall. The variation of the attack angle has great influence on the endwall heat transfer, The endwall fitted with turbulators with an aspect ratio (length/height) of 2 and attack angle of 45-deg provides the highest thermal-hydraulic performance with a relatively low pressure drop penalty as long lasting longitudinal vortices might be induced at this attack angle and the heat transfer is observed to be enhanced at the downstream part of the endwall. In addition, for the temperature uniformity on the endwall, the local heat transfer at the upstream part still has the potential to be further improved for all studied cases. The optimal thermalhydraulic performance is increased by more than 24% compared with that on the endwall in the smooth U duct. This novel design presents a rather high overall thermal performance compared with the traditional design in the open literature.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering (hsv//eng)

Nyckelord

Endwall heat transfer
Experiment
Liquid crystal thermography
Two-pass duct
Winglet vortex generators

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Luo, Lei
Zhao, Zhiqi
Qiu, Dandan
Wang, Songtao
Wang, Zhongqi
Sundén, Bengt
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Maskinteknik
Artiklar i publikationen
International Jo ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy