SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:7539ee43-ad99-4ce7-97ef-de2b67eaf944"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:7539ee43-ad99-4ce7-97ef-de2b67eaf944" > A miniaturised elec...

A miniaturised electrochemical affinity assay based on a wall-free sample droplet and micro-dispensing of the redox-labelled binding partner

Mosbach, M. (författare)
Laurell, Thomas (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
Nilsson, J. (författare)
visa fler...
Csöregi, Elisabeth (författare)
Lund University,Lunds universitet,Centrum för analys och syntes,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Centre for Analysis and Synthesis,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
Schuhmann, W. (författare)
visa färre...
 (creator_code:org_t)
Elsevier BV, 2001
2001
Engelska.
Ingår i: Biosensors & Bioelectronics. - : Elsevier BV. - 1873-4235 .- 0956-5663. ; 16:9-12, s. 611-620
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • An affinity-assay was developed that is based on the modulation of the diffusion coefficient of a redox-labelled hapten upon complementary recognition of the analyte leading to an increase of molecular weight and hence to a decrease of the diffusion coefficient. The slower diffusion is monitored by means of cyclic voltammetry. In order to demonstrate the feasibility of this assay format, recognition of biotin by streptavidin has been chosen as a model system. Labelling of biotin was achieved by covalent binding of a ferrocene derivative to the biotin unit. To reduce the consumption of expensive compounds and to allow automatisation of the assay a novel miniaturised set-up was developed based on a wall-free sample droplet which forms the electrochemical cell with typical volumes of up to 10 mul. This droplet is dispensed by means of a step-motor driven syringe pump through a specially designed electrode holder spanning the gap between a micro-working electrode and a macroscopic counter electrode. By means of a piezo-driven micro-dispenser a predefined number of nano-droplets (100 pl volume each) containing the redox-labelled hapten are shot into the sample droplet. By this, any physical contact and hence any cross-contamination between the sample and the reagent solution could be avoided. Signal amplification can be achieved by redox recycling between the micro-electrode and the perpendicular positioned macroscopic counter electrode. (C) 2001 Elsevier Science B.V. All rights reserved.

Ämnesord

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Medicinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering (hsv//eng)

Nyckelord

AVIDIN
TECHNOLOGY
MALDI
BIOTIN INTERACTION
CAPILLARY-ELECTROPHORESIS
FLOW-THROUGH DISPENSER
streptavidin
miniaturisation
micro-dispenser
immunoassay
biotin
diffusion coefficient

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Mosbach, M.
Laurell, Thomas
Nilsson, J.
Csöregi, Elisabe ...
Schuhmann, W.
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Kemi
och Analytisk kemi
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
Artiklar i publikationen
Biosensors & Bio ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy