Sökning: id:"swepub:oai:lup.lub.lu.se:76c05a26-4f48-4f71-ba85-3c7119ad7688" >
High performance mu...
High performance multiplex acoustophoresis for WBC subpopulation isolation
-
- Lenshof, Andreas (författare)
- Lund University,Lunds universitet,NanoLund: Centre for Nanoscience,Annan verksamhet, LTH,Lunds Tekniska Högskola,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Acoustofluidics group,Forskargrupper vid Lunds universitet,Other operations, LTH,Faculty of Engineering, LTH,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH,Lund University Research Groups
-
- Urbansky, Anke (författare)
- Lund University,Lunds universitet,NanoLund: Centre for Nanoscience,Annan verksamhet, LTH,Lunds Tekniska Högskola,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Acoustofluidics group,Forskargrupper vid Lunds universitet,Other operations, LTH,Faculty of Engineering, LTH,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH,Lund University Research Groups
-
- Scheding, Stefan (författare)
- Lund University,Lunds universitet,Skåne University Hospital
-
visa fler...
-
- Laurell, Thomas (författare)
- Lund University,Lunds universitet,NanoLund: Centre for Nanoscience,Annan verksamhet, LTH,Lunds Tekniska Högskola,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Acoustofluidics group,Forskargrupper vid Lunds universitet,Other operations, LTH,Faculty of Engineering, LTH,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH,Lund University Research Groups,Dongguk University, Seoul
-
visa färre...
-
(creator_code:org_t)
- 2017
- 2017
- Engelska 2 s.
-
Ingår i: MicroTAS 2017 : Savannah, Georgia, USA - Savannah, Georgia, USA. - 1556-5904. - 9780692941836 ; 2017, s. 1385-1386
- Relaterad länk:
-
https://lup.lub.lu.s...
Abstract
Ämnesord
Stäng
- Recently, acoustophoresis has been used to fractionate white blood cells (WBC) into subpopulations, Grenvall et al. [1]. However, at a sample throughput of 8-10 μl/min the separation has limited bioanalytical application. In order to substantially increase throughput, we have redesigned and developed a new separation system that enables unmatched WBC separation performance at a volume throughput of 200μl/min and a cell concentration of 106 cells/ml.
Ämnesord
- NATURVETENSKAP -- Kemi -- Analytisk kemi (hsv//swe)
- NATURAL SCIENCES -- Chemical Sciences -- Analytical Chemistry (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Medicinsk bioteknologi -- Biomedicinsk laboratorievetenskap/teknologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Medical Biotechnology -- Biomedical Laboratory Science/Technology (hsv//eng)
Nyckelord
- Acoustophoresis
- Cell isolation
- High-throughput
- WBC
Publikations- och innehållstyp
- kon (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas