SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:7739d0e5-8ea0-4c74-ae22-886fc8fc0ee9"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:7739d0e5-8ea0-4c74-ae22-886fc8fc0ee9" > Molecular imaging w...

Molecular imaging with endogenous substances

Golman, Klaes (författare)
Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,Radiology Diagnostics, Malmö,Lund University Research Groups
Ardenaer-Larsen, JH (författare)
Petersson, JS (författare)
visa fler...
Månsson, Sven (författare)
Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,Radiology Diagnostics, Malmö,Lund University Research Groups
Leunbach, I (författare)
visa färre...
 (creator_code:org_t)
2003-08-20
2003
Engelska.
Ingår i: Proceedings of the National Academy of Sciences. - : Proceedings of the National Academy of Sciences. - 1091-6490 .- 0027-8424. ; 100:18, s. 10435-10439
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Dynamic nuclear polarization has enabled hyperpolarization of nuclei such as C-13 and N-15 in endogenous substances. The resulting high nuclear polarization makes it possible to perform subsecond C-13 MRI. By using the dynamic nuclear polarization hyperpolarization technique, 10% polarization was obtained in an aqueous solution of 100 mM C-13-labeled urea, ready for injection. The in vivo T, relaxation time of C-13 in the urea solution was determined to 20 +/- 2 s. Due to the long relaxation time, it is possible to use the hyperpolarized substance for medical imaging. A series of high-resolution (approximate to1-mm) magnetic resonance images were acquired, each with a scan time of 240 ms, 0-5 s after an i.v. injection of the hyperpolarized aqueous [C-13]urea solution in a rat. The results show that it is possible to perform C-13 angiography with a signal-to-noise ratio of approximate to275 in approximate to0.25 s. Perfusion studies with endogenous substances may allow higher spatial and/or temporal resolution than is possible with current proton imaging techniques.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Golman, Klaes
Ardenaer-Larsen, ...
Petersson, JS
Månsson, Sven
Leunbach, I
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Proceedings of t ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy