SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:775af411-06d9-4d7e-afc3-d756dd0d6447"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:775af411-06d9-4d7e-afc3-d756dd0d6447" > A new liposomal liv...

A new liposomal liver-specific contrast agent for CT: first human phase-I clinical trial assessing efficacy and safety

Leander, Peter (författare)
Lund University,Lunds universitet,Diagnostisk radiologi, Malmö,Forskargrupper vid Lunds universitet,Radiology Diagnostics, Malmö,Lund University Research Groups
Höglund, Peter (författare)
Lund University,Lunds universitet,Avdelningen för klinisk kemi och farmakologi,Institutionen för laboratoriemedicin,Medicinska fakulteten,Division of Clinical Chemistry and Pharmacology,Department of Laboratory Medicine,Faculty of Medicine
Borseth, Arve (författare)
visa fler...
Kloster, Yngvil (författare)
Berg, Arne (författare)
visa färre...
 (creator_code:org_t)
Springer Science and Business Media LLC, 2001
2001
Engelska.
Ingår i: European Radiology. - : Springer Science and Business Media LLC. - 0938-7994 .- 1432-1084. ; 11:4, s. 698-704
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In this first clinical trial liposome-encapsulated iodixanol, CT particles (CTP) were studied. The aims of the present trial were to assess the efficacy of CTP in CT and to determine the safety of different doses of CTP. A total of 47 healthy volunteers were enrolled in the present study. The CTP was administered at doses 10, 30, 70 and 100 mg encapsulated I/kg bw. Efficacy was assessed using single-slice CT of the abdomen and evaluated by dose-response attenuation curves over time in liver, spleen, and abdominal vessels. Safety was assessed by blood tests, clinical examinations and recording of subjective adverse events (AE). The attenuations in liver tissue increased with the dose and maximal values above baseline were 20, 39 and 45 HU at the doses 30, 70 and 100 mg encapsulated I/kg bw, respectively. Maximal increases were seen 12.5 min after contrast administration. As for liver, the attenuations in spleen increased with the dose, but higher attenuations were obtained. In early images clinically significant enhancement was seen in abdominal vessels. Mild and moderate subjective AE were encountered at the doses 70 and 100 mg encapsulated I/kg bw. The CTP is efficacious in enhancing hepatic and splenic tissues and in early imaging of abdominal vessels. Adverse event precludes a clinical use of CTP in the current formulation.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Liver
CT
Liposome encapsulated
Contrast media

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Leander, Peter
Höglund, Peter
Borseth, Arve
Kloster, Yngvil
Berg, Arne
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
European Radiolo ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy