SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:7a52c041-8cab-4eb0-b840-c1412822dfcc"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:7a52c041-8cab-4eb0-b840-c1412822dfcc" > Microembolic signal...

Microembolic signal counts increase during hyperbaric exposure in patients with prosthetic heart valves

Baumgartner, R W (författare)
Frick, A (författare)
Kremer, Christine (författare)
Lund University,Lunds universitet,Sektion IV,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Section IV,Department of Clinical Sciences, Lund,Faculty of Medicine
visa fler...
Oechslin, E (författare)
Russi, E (författare)
Turina, J (författare)
Georgiadis, D (författare)
visa färre...
 (creator_code:org_t)
Elsevier BV, 2001
2001
Engelska.
Ingår i: Journal of Thoracic and Cardiovascular Surgery. - : Elsevier BV. - 1097-685X .- 0022-5223. ; 122:6, s. 1142-1146
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BACKGROUND: Patients with prosthetic heart valves have an increased risk of thromboembolic events, and transcranial Doppler sonography reveals microembolic signals. Whereas microembolic signals were initially assumed to be of particulate matter, recent studies suggest that they are partially gaseous in origin. If this is true, alteration of environmental pressure should change microembolic signal counts. We undertook this study to evaluate the influence of hyperbaric exposure on microembolic signal counts in persons with prosthetic heart valves. METHODS AND RESULTS: Microembolic signal counts were monitored by transcranial Doppler sonography of both middle cerebral arteries under normobaria (normobaria 1), 2 subsequent periods of hyperbaria (2.5 and 1.75 bar), and a second period of normobaria (normobaria 2) in 15 patients with prosthetic heart valves. Each monitoring period lasted 30 minutes. Compression and decompression rates were 0.1 bar/min. Microembolic signal counts increased from 20 (12-78) at normobaria 1 to 79 (30-165) at 2.5 bar (P <.01 vs normobaria 1 and 2), decreased to 44 (18-128) at 1.75 bar (P <.01 vs normobaria 1 and 2.5 bar; P <.001 vs normobaria 2), and returned to 20 (8-96) at normobaria 2 (values are medians and 95% confidence intervals). CONCLUSIONS: Our results strongly suggest that gaseous bubbles are underlying material for part of the microembolic signals detected in patients with prosthetic heart valves.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Neurologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Neurology (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy