SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:7c3b4afe-2777-4f88-848f-45e98160f189"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:7c3b4afe-2777-4f88-848f-45e98160f189" > Inverse vs. forward...

Inverse vs. forward breast IMRT planning

Mihai, A (författare)
Rakovitch, E (författare)
Sixel, K (författare)
visa fler...
Woo, T (författare)
Cardoso, M (författare)
Bell, C (författare)
Ruschin, Mark (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
Pignol, JP (författare)
visa färre...
 (creator_code:org_t)
Elsevier BV, 2005
2005
Engelska.
Ingår i: Medical Dosimetry. - : Elsevier BV. - 1873-4022 .- 0958-3947. ; 30:3, s. 149-154
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Breast intensity-modulated radiation therapy (IMRT) improves dose distribution homogeneity within the whole breast. Previous publications report the use of inverse or forward dose optimization algorithms. Because the inverse technique is not widely available in commercial treatment planning systems, it is important to compare the 2 algorithms. The goal of this work is to compare them on a prospective cohort of 30 patients. Dose distributions were evaluated on differential dose-volume histograms using the volumes receiving more than 105% (V-105) and 110% (V-110) of the prescribed dose, and on the maximum dose (D-max) or hot spot and the sagittal dose gradient (SDG) being the gradient between the dose on inframammary crease and the dose prescribed. The data were analyzed using Wilcoxon signed rank test. The inverse planning significantly improves the V-105 (mean value 9.7% vs. 14.5%, p = 0.002), and the V-110 (mean value 1.4% vs. 3.2%, p = 0.006). However, the SDG is not statistically significantly different for either algorithm. Looking at the potential impact on skin acute reaction, although there is a significant reduction of V-110 using an inverse algorithm, it is unlikely this 1.6% volume reduction will present a significant clinical advantage over a forward algorithm. Both algorithms are equivalent in removing the hot spots on the inframammary fold, where acute skin reactions occur more frequently using a conventional wedge technique. Based on these results, we recommend that both forward and inverse algorithms should be considered for breast IMRT planning.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

inverse IMRT
breast cancer
adjuvant radiotherapy
forward IMRT

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy