SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:80c7c66d-9c29-4a60-9340-ea02d987d0d2"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:80c7c66d-9c29-4a60-9340-ea02d987d0d2" > Local Flip Angle Co...

Local Flip Angle Correction for Improved Volume T1-Quantification in Three-Dimensional dGEMRIC Using the Look-Locker Technique

Siversson, Carl (författare)
Lund University,Lunds universitet,Enheten för led- och mjukvävnadsforskning,Forskargrupper vid Lunds universitet,Medicinsk strålningsfysik, Malmö,Joint and Soft Tissue Unit,Lund University Research Groups,Medical Radiation Physics, Malmö
Tiderius, Carl Johan (författare)
Lund University,Lunds universitet,Ortopedi - klinisk och molekylär osteoporosforskning,Forskargrupper vid Lunds universitet,Enheten för led- och mjukvävnadsforskning,Orthopedics - Clinical and Molecular Osteoporosis Research,Lund University Research Groups,Joint and Soft Tissue Unit
Dahlberg, Leif (författare)
Lund University,Lunds universitet,Enheten för led- och mjukvävnadsforskning,Forskargrupper vid Lunds universitet,Joint and Soft Tissue Unit,Lund University Research Groups
visa fler...
Svensson, Jonas (författare)
Lund University,Lunds universitet,Enheten för led- och mjukvävnadsforskning,Forskargrupper vid Lunds universitet,Medicinsk strålningsfysik, Malmö,Joint and Soft Tissue Unit,Lund University Research Groups,Medical Radiation Physics, Malmö
visa färre...
 (creator_code:org_t)
Wiley, 2009
2009
Engelska.
Ingår i: Journal of Magnetic Resonance Imaging. - : Wiley. - 1522-2586 .- 1053-1807. ; 30:4, s. 834-841
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose: To present an evaluation method for three-dimensional Look-Locker (3D-LL) based T1 quantification, calculating correct T1 values independent of local flip angle (FA) variations. The method was evaluated both in phantoms and in vivo in a delayed Gadolinium Enhanced MRI of Cartilage (dGEMRIC) study with 33 subjects. Materials and Methods: T1 was measured with 3D-LL, using both local FA correction and a precalculated FA slice profile. and compared with standard constant FA correction, for all slices in phantoms and in both femur condyles in vivo. T1 measured using two-dimensional Inversion Recovery (2D-IR) was used as gold standard. Results: Due to the FA being slice dependent, the standard constant FA correction results in erroneous T1 (systematic error = 109.1 ms in vivo), especially in the outer slices. With local FA correction. the calculated T1 is excellent for all slices in phantoms (<5% deviation from 2D-IR). In vivo the performance is lower (systematic error = -57.5ms), probably due to imperfect inversion. With precalculated FA correction the performance is very good also in vivo (systematic error = 13.3 ms). Conclusion: With the precalculated FA correction method, the 3D-LL sequence is robust enough for in vivo dGEMRIC, even outside the centermost slices.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

dGEMRIC
B1 correction
flip angle correction
Look-Locker
T1 mapping
cartilage

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Siversson, Carl
Tiderius, Carl J ...
Dahlberg, Leif
Svensson, Jonas
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Journal of Magne ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy