Sökning: id:"swepub:oai:lup.lub.lu.se:881a6bf2-78b7-4228-9ffd-b239e947cefd" >
Experimental test o...
Experimental test on the performance of a −80 °C cascade refrigeration unit using refrigerants R290-R170 for COVID-19 vaccines storage
-
- Liu, Zhan (författare)
- Lund University,Lunds universitet,Värmeöverföring,Institutionen för energivetenskaper,Institutioner vid LTH,Lunds Tekniska Högskola,Heat Transfer,Department of Energy Sciences,Departments at LTH,Faculty of Engineering, LTH,State Key Laboratory for GeoMechanics and Deep Underground Engineering
-
- Bai, Minkai (författare)
- State Key Laboratory for GeoMechanics and Deep Underground Engineering
-
- Tan, Haihui (författare)
- University of Electronic Science and Technology of China
-
visa fler...
-
- Ling, Yunzhi (författare)
- State Key Laboratory for GeoMechanics and Deep Underground Engineering
-
- Cao, Zhen (författare)
- Lund University,Lunds universitet,NanoLund: Centre for Nanoscience,Annan verksamhet, LTH,Lunds Tekniska Högskola,Värmeöverföring,Institutionen för energivetenskaper,Institutioner vid LTH,LTH profilområde: Nanovetenskap och halvledarteknologi,LTH profilområden,LU profilområde: Ljus och material,Lunds universitets profilområden,Other operations, LTH,Faculty of Engineering, LTH,Heat Transfer,Department of Energy Sciences,Departments at LTH,Faculty of Engineering, LTH,LTH Profile Area: Nanoscience and Semiconductor Technology,LTH Profile areas,Faculty of Engineering, LTH,LU Profile Area: Light and Materials,Lund University Profile areas
-
visa färre...
-
(creator_code:org_t)
- Elsevier BV, 2023
- 2023
- Engelska.
-
Ingår i: Journal of Building Engineering. - : Elsevier BV. - 2352-7102. ; 63
- Relaterad länk:
-
http://dx.doi.org/10... (free)
-
visa fler...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- With the urgent demand for ultralow-temperature refrigerators worldwide, the operation reliability and stability of the refrigeration system becomes greatly crucial. In this study, a -80 oC ultralow-temperature cascade refrigeration system (CRS) is developed. From aspects of global warming potential (GWP) and ozone depletion potential (ODP), the environmentally friendly refrigerants R290 and R170 are utilized in the high-temperature cycle and low-temperature cycle of CRS. The experimental measurement is conducted in a Type-laboratory with a dry bulb temperature of 25.0 °C and a wet bulb temperature of 20.2 °C. The pull-down and stable operation performance of the CRS freezer are experimentally investigated. Both the inlet and outlet temperature and pressure of two compressors are monitored, and the operation characteristic of the CRS is analyzed. With some temperature test points arranged in the freezer, the temperature drop and temperature fluctuation variation of air are assessed. The operation power consumption of the CRS is also measured during the whole process. It shows that the −80 °C temperature can be generated and realized by the developed ultralow-temperature freezer.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Maskinteknik -- Energiteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Mechanical Engineering -- Energy Engineering (hsv//eng)
Nyckelord
- -80 °C ultralow-temperature
- Cascade refrigeration system
- COVID-19 vaccines storage
- Refrigerant pair R290-R170
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas