Effects of B(1) inhomogeneity correction for three-dimensional variable flip angle T(1) measurements in hip dGEMRIC at 3 T and 1.5 T.

Siversson, Carl (författare)
Lund University,Lunds universitet,Enheten för led- och mjukvävnadsforskning,Forskargrupper vid Lunds universitet,Medicinsk strålningsfysik, Malmö,Joint and Soft Tissue Unit,Lund University Research Groups,Medical Radiation Physics, Malmö
Chan, Jenny (författare)
Tiderius, Carl Johan (författare)
Lund University,Lunds universitet,Enheten för led- och mjukvävnadsforskning,Forskargrupper vid Lunds universitet,Joint and Soft Tissue Unit,Lund University Research Groups
visa fler...
Mamisch, Tallal Charles (författare)
Jellus, Vladimir (författare)
Svensson, Jonas (författare)
Lund University,Lunds universitet,Enheten för led- och mjukvävnadsforskning,Forskargrupper vid Lunds universitet,Medicinsk strålningsfysik, Malmö,Joint and Soft Tissue Unit,Lund University Research Groups,Medical Radiation Physics, Malmö
Kim, Young-Jo (författare)
visa färre...
 (creator_code:org_t)
2011-08-29
2012
Engelska.
Ingår i: Magnetic Resonance in Medicine. - : Wiley. - 1522-2594 .- 0740-3194. ; 67:6, s. 1776-1781
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Delayed gadolinium-enhanced MRI of cartilage is a technique for studying the development of osteoarthritis using quantitative T(1) measurements. Three-dimensional variable flip angle is a promising method for performing such measurements rapidly, by using two successive spoiled gradient echo sequences with different excitation pulse flip angles. However, the three-dimensional variable flip angle method is very sensitive to inhomogeneities in the transmitted B(1) field in vivo. In this study, a method for correcting for such inhomogeneities, using an additional B(1) mapping spin-echo sequence, was evaluated. Phantom studies concluded that three-dimensional variable flip angle with B(1) correction calculates accurate T(1) values also in areas with high B(1) deviation. Retrospective analysis of in vivo hip delayed gadolinium-enhanced MRI of cartilage data from 40 subjects showed the difference between three-dimensional variable flip angle with and without B(1) correction to be generally two to three times higher at 3 T than at 1.5 T. In conclusion, the B(1) variations should always be taken into account, both at 1.5 T and at 3 T. Magn Reson Med, 2011. © 2011 Wiley-Liss, Inc.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

B1 correction
T1 mapping
dGEMRIC
cartilage

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy