SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:913714bd-207a-4009-a057-9220411d460c"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:913714bd-207a-4009-a057-9220411d460c" > The radiation dose ...

The radiation dose to children from X-ray examinations of the pelvis and the urinary tract

Almén, A (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups,Skåne University Hospital
Mattsson, S (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups,Skåne University Hospital
 (creator_code:org_t)
British Institute of Radiology, 1995
1995
Engelska 10 s.
Ingår i: British Journal of Radiology. - : British Institute of Radiology. - 0007-1285 .- 1748-880X. ; 68:810, s. 13-604
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • X-ray examinations of the pelvis and the urinary tract are frequent examinations of children, in which a large part of the trunk is irradiated. The irradiated volume contains many of the most radiation sensitive organs and tissues. The absorbed dose to children during the examination was estimated from measurements with a dose-area product meter and thermoluminescent dosemeters (TLDs). Entrance surface dose and the dose-area product results are presented. Conversion factors between the entrance surface dose and the organ dose were derived. The energy imparted, organ dose and effective dose were determined. The entrance surface dose for one single exposure varied between 0.32 mGy and 8.6 mGy for the urinary tract examination and between 0.26 mGy and 2.89 mGy per exposure for the pelvis examination. These variations are mainly influenced by the body size of the patient. The number of images taken during one examination varied. For the urinary tract investigation, the average number of exposures was six, while the corresponding number for the pelvis examination was two. The average effective dose for a typical urinary tract investigation ranged from 0.9 mSv to 8.5 mSv and from 0.3 mSv to 1.4 mSv for the pelvis examination. The radiation dose depends greatly on the body size. The recommendations to present the results in relation to age have been followed; however, the variation of body size even within each specified age range is significant. It is suggested that doses should be quoted in relation to a more critical parameter than age.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Adolescent
Age Factors
Child
Child, Preschool
Energy Transfer
Female
Humans
Infant
Infant, Newborn
Male
Pelvis/diagnostic imaging
Radiation Dosage
Radiometry/methods
Sex Factors
Skin/radiation effects
Urography/methods

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Almén, A
Mattsson, S
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
British Journal ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy