Sökning: id:"swepub:oai:lup.lub.lu.se:9144696a-ae23-4453-ba82-110c7da34206" >
Orthodontic applian...
Orthodontic appliances and MR image artefacts : An exploratory in vitro and in vivo study using 1.5-T and 3-T scanners
-
- Sonesson, Mikael (författare)
- Malmö universitet,Malmö University,Odontologiska fakulteten (OD)
-
- Al Qabandi, Fahad (författare)
- Malmö universitet,Malmö University,Odontologiska fakulteten (OD)
-
- Månsson, Sven (författare)
- Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups,Lund Univ, Skane Univ Hosp, Dept Translat Med, Med Radiat Phys, Malmo, Sweden.
-
visa fler...
-
- Abdulraheem, Salem (författare)
- Malmö universitet,Malmö University,Al Jahra Specialized Dental Center,Odontologiska fakulteten (OD),Department of Orthodontics, Al-Jahra Specialty Dental Center, Ministry of Health, Kuwait
-
- Bondemark, Lars (författare)
- Malmö universitet,Malmö University,Odontologiska fakulteten (OD)
-
- Hellén-Halme, Kristina (författare)
- Malmö universitet,Malmö University,Odontologiska fakulteten (OD)
-
visa färre...
-
(creator_code:org_t)
- Korean Academy of Oral and Maxillofacial Radiology, 2021
- 2021
- Engelska 13 s.
-
Ingår i: Imaging Science in Dentistry. - : Korean Academy of Oral and Maxillofacial Radiology. - 2233-7822 .- 2233-7830. ; 51
- Relaterad länk:
-
http://dx.doi.org/10... (free)
-
visa fler...
-
https://doi.org/10.5...
-
https://doi.org/10.5...
-
https://isdent.org/D...
-
https://mau.diva-por... (primary) (Raw object)
-
https://lup.lub.lu.s...
-
https://doi.org/10.5...
-
https://urn.kb.se/re...
-
visa färre...
Abstract
Ämnesord
Stäng
- Purpose: The aim of this study was to assess the artefacts of 12 fixed orthodontic appliances in magnetic resonance images obtained using 1.5-T and 3-T scanners, and to evaluate different imaging sequences designed to suppress metal artefacts. Materials and Methods: In vitro, study casts of 1 adult with normal occlusion were used. Twelve orthodontic appliances were attached to the study casts and scanned. Turbo spin echo (TSE), TSE with high readout bandwidth, and TSE with view angle tilting and slice encoding for metal artefact correction were used to suppress metal artefacts. Artefacts were measured. In vivo, 6 appliances were scanned: 1) conventional stainless-steel brackets; 2) nickelfree brackets; 3) titanium brackets; 4) a Herbst appliance; 5) a fixed retainer; and 6) a rapid maxillary expander. The maxilla, mandible, nasopharynx, tongue, temporomandibular joints, and cranial base/eye globes were assessed. Scores of 0, 1, 2, and 3 indicated no artefacts and minor, moderate, and major artefacts, respectively. Results: In vitro, titanium brackets and the fixed retainer created minor artefacts. In vivo, titanium brackets caused minor artefacts. Conventional stainless-steel and nickel free brackets, the fixed retainer, and the rapid maxillary expander caused major artefacts in the maxilla and mandible. Conventional stainless-steel and nickel-free brackets caused major artefacts in the eye globe (3-T). TSE with high readout bandwidth reduced image artefacts in both scanners. Conclusion: Titanium brackets, the Herbst appliance, and the fixed retainer caused minor artefacts in images of neurocranial structures(1.5-T and 3-T) when using TSE with high readout bandwidth.(Imaging Sci Dent 20200199)
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Odontologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Dentistry (hsv//eng)
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
Nyckelord
- Artifacts
- Magnetic Resonance Imaging
- Orthodontic Appliances
- Skull
- Artifacts
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas