Bayesian algorithm to estimate position and activity of an orphan gamma source utilizing multiple detectors in a mobile gamma spectrometry system

Bukartas, Antanas (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
Wallin, Jonas (författare)
Lund University,Lunds universitet,Statistiska institutionen,Ekonomihögskolan,Department of Statistics,Lund University School of Economics and Management, LUSEM
Finck, Robert (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
visa fler...
Rääf, Christopher (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
visa färre...
 (creator_code:org_t)
2021-01-22
2021
Engelska.
Ingår i: PLoS ONE. - : Public Library of Science (PLoS). - 1932-6203. ; 16:1 January
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • To avoid harm to the public and the environment, lost ionizing radiation sources must be found and brought back under the regulatory control as soon as possible. Usually, mobile gamma spectrometry systems are used in such search missions. It is possible to estimate the position and activity of point gamma sources by performing Bayesian inference on the measurement data. The aim of this study was to theoretically investigate the improvements in the Bayesian estimations of the position and activity of a point gamma source due to introduction of data from multiple detectors with angular variations of efficiency. Three detector combinations were tested - a single 123% HPGe detector, single 4l NaI (Tl) detector and a 123% HPGe with 2x4l NaI (Tl) detector combination - with and without angular efficiency variations for each combination resulting in six different variants of the Bayesian algorithm. It was found that introduction of angular efficiency variations of the detectors did improve the accuracy of activity estimation slightly, while introduction of data from additional detectors lowered the signal-to-noise ratio threshold of the system significantly, increasing the stability and accuracy of the estimated source position and activity, for a given signal-to-noise ratio.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

  • PLoS ONE (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Bukartas, Antana ...
Wallin, Jonas
Finck, Robert
Rääf, Christophe ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
PLoS ONE
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy