SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:9a12af85-a6f5-41ec-9281-0b00e615c15e"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:9a12af85-a6f5-41ec-9281-0b00e615c15e" > Measurements of kne...

Measurements of knee rotation-reliability of an external device in vivo.

Almquist, Per O (författare)
Ekdahl, Charlotte (författare)
Lund University,Lunds universitet,Människan i rörelse: hälsa och rehabilitering,Forskargrupper vid Lunds universitet,Human Movement: health and rehabilitation,Lund University Research Groups
Isberg, Per-Erik (författare)
visa fler...
Fridén, Thomas (författare)
visa färre...
 (creator_code:org_t)
2011-12-30
2011
Engelska.
Ingår i: BMC Musculoskeletal Disorders. - : Springer Science and Business Media LLC. - 1471-2474. ; 12
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BACKGROUND: Knee rotation plays an important part in knee kinematics during weight-bearing activities. An external device for measuring knee rotation (the Rottometer) has previously been evaluated for validity by simultaneous measurements of skeletal movements with Roentgen Stereometric Analysis (RSA). The aim of this study was to investigate the reliability of the device. METHOD: The within-day and test-retest reliability as well as intertester reliability of the device in vivo was calculated. Torques of 3, 6 and 9 Nm and the examiner's apprehension of end-feel were used at 90°, 60° and 30° of knee flexion. Intraclass Correlation Coefficient 2,1 (ICC 2,1), 95% confidence interval (CI) of ICC and 95% CI between test trials and examiners were used as statistical tests. RESULT: ICC2,1 ranged from 0.50 to 0.94 at all three flexion angles at 6 and 9 Nm as well as end-feel, and from 0.22 to 0.75 at 3 Nm applied torque. CONCLUSION: The Rottometer was a reliable measurement instrument concerning knee rotation at the three different flexion angles (90°, 60° and 30°) with 6 and 9 Nm applied torques as well as the examiner's apprehension of end-feel. Three Nm was not a reliable torque. The most reliable measurements were made at 9 Nm applied torque.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Ortopedi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Orthopaedics (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Almquist, Per O
Ekdahl, Charlott ...
Isberg, Per-Erik
Fridén, Thomas
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Ortopedi
Artiklar i publikationen
BMC Musculoskele ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy