SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:9cdb8b6c-e05d-4982-8cc4-611cc26c7bfe"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:9cdb8b6c-e05d-4982-8cc4-611cc26c7bfe" > Contaminations of s...

Contaminations of soil and two capsicum annuum generations irrigated by reused urban wastewater treated by different reed beds

Almuktar, Suhad A.A.A.N. (författare)
University of Salford,University of Basrah
Abed, Suhail N. (författare)
University of Salford
Scholz, Miklas (författare)
Lund University,Lunds universitet,Avdelningen för Teknisk vattenresurslära,Institutionen för bygg- och miljöteknologi,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Water Resources Engineering,Department of Building and Environmental Technology,Departments at LTH,Faculty of Engineering, LTH,University of Johannesburg,University of Salford
 (creator_code:org_t)
2018-08-18
2018
Engelska.
Ingår i: International Journal of Environmental Research and Public Health. - : MDPI AG. - 1661-7827 .- 1660-4601. ; 15:8
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: In order to save potable water, this study aims to evaluate the contamination of soil and Capsicum annuum L. (chilli) watered with urban wastewater (sewage) pre-treated by various wetland systems. Methods: The appropriateness of wetland outflow for irrigation when applying reused wastewater with high contamination of minerals and pathogens was assessed. The impact of wastewaters pre-treated by various wetlands on soil and harvest was tested in terms of mineral and biological contamination risk. Results: The wetlands met the standards for irrigation water for most water quality variables. However, the thresholds for key water quality parameters were significantly (p < 0.05) exceeded. The highest values for total coliforms, ammonium-nitrogen, phosphorus and potassium were 157,072 CFU/100 mL, 8.5 mg/L, 5.0 mg/L, and 7.0 mg/L, respectively. The harvest was moderately polluted only by zinc according to vegetable quality standards (threshold of 50 mg/kg). Zinc concentrations for Filters 2, 4, 6, 7 and 8 were 35.8, 60.6, 65.1, 65.5 and 53.2 mg/kg, respectively. No bacterial contamination was detected. Conclusions: Treatment of domestic wastewater applying constructed wetlands and subsequent recycling of the treated wastewater for irrigation of crops is a good substitute to the traditional application of drinking water for irrigation purposes.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Naturresursteknik -- Miljöledning (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Environmental Engineering -- Environmental Management (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Vattenteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Water Engineering (hsv//eng)

Nyckelord

Constructed wetland
Cultivar
Ecological engineering
Irrigation water quality
Sewage treatment
Sustainable development
Zinc

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Almuktar, Suhad ...
Abed, Suhail N.
Scholz, Miklas
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Naturresurstekni ...
och Miljöledning
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Samhällsbyggnads ...
och Vattenteknik
Artiklar i publikationen
International Jo ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy