SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:9d165fa8-4ce4-40cc-b8da-36cdf2d0f47d"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:9d165fa8-4ce4-40cc-b8da-36cdf2d0f47d" > Reference Region-Ba...

Reference Region-Based Pharmacokinetic Modeling in Quantitative Dynamic Contract-Enhanced MRI Allows Robust Treatment Monitoring in a Rat Liver Tumor Model Despite Cardiovascular Changes

Steingoetter, Andreas (författare)
Svensson, Jonas (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
Kosanke, Yvonne (författare)
visa fler...
Botnar, Rene M. (författare)
Schwaiger, Markus (författare)
Rummeny, Ernst (författare)
Braren, Rickmer (författare)
visa färre...
 (creator_code:org_t)
2010-09-24
2011
Engelska.
Ingår i: Magnetic Resonance in Medicine. - : Wiley. - 1522-2594 .- 0740-3194. ; 65:1, s. 229-238
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In this work, two pharmacokinetic modeling techniques, population arterial input function model, and reference region model, were applied to dynamic contract-enhanced MRI data, to test the influence of a change in heart rate on modeling parameters. A rat population arterial input function was generated by dynamic contrast-enhanced computed tomography measurements using the MR contrast agent gadolinium diethylenetriamine penta-acetic acid. Then, dynamic contract-enhanced MRI was used for treatment monitoring in two groups of hepatocellular carcinoma bearing rats. Whereas group 1 had the same heart rate as animals analyzed for the population arterial input function (263 +/- 20 bpm), group 2 had a higher heart rate (369 +/- 11 bpm) due to a different anesthesia protocol. The pharmacokinetic modeling parameters volume transfer constant K-trans and relative extravascular extracellular space v(e) were calculated with both models and statistically compared. For group 1, good correlation and agreement was found between the models showing no difference in K-trans and v(e) (Delta K-trans:4 +/- 19% and Delta v(e):4 +/- 12%, P = 0.2). In contrast, for group 2, a bias in parameter values for the population arterial input function model was detected (Delta K-trans: -45 +/- 7% and Delta v(e):-31 +/- 7%, P <= 0.001). The presented work underlines the value of the reference region model in longitudinal treatment monitoring and provides a straightforward approach for the generation of a rat population arterial input function. Magn Reson Med 65: 229-238, 2011. (C) 2010 Wiley-Liss, Inc.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

quantitative dynamic contract-enhanced MRI
population arterial input
function
reference region model
hepatocellular carcinoma rat tumor
model

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy