Measurements of the Electrical Incidence Angle Modifiers of an Asymmetrical Photovoltaic/Thermal Compound Parabolic Concentrating-Collector

Bernardo, Ricardo (författare)
Lund University,Lunds universitet,Avdelningen för Energi och byggnadsdesign,Institutionen för bygg- och miljöteknologi,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Energy and Building Design,Department of Building and Environmental Technology,Departments at LTH,Faculty of Engineering, LTH
Davidsson, Henrik (författare)
Lund University,Lunds universitet,Avdelningen för Energi och byggnadsdesign,Institutionen för bygg- och miljöteknologi,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Energy and Building Design,Department of Building and Environmental Technology,Departments at LTH,Faculty of Engineering, LTH
Gentile, Niko (författare)
Lund University,Lunds universitet,Avdelningen för Energi och byggnadsdesign,Institutionen för bygg- och miljöteknologi,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Energy and Building Design,Department of Building and Environmental Technology,Departments at LTH,Faculty of Engineering, LTH
visa fler...
Gomes, João (författare)
Gruffman, Christian (författare)
Chea, Luís (författare)
Chabu, Mumba (författare)
Karlsson, Björn (författare)
Lund University,Lunds universitet,Avdelningen för Energi och byggnadsdesign,Institutionen för bygg- och miljöteknologi,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Energy and Building Design,Department of Building and Environmental Technology,Departments at LTH,Faculty of Engineering, LTH
visa färre...
 (creator_code:org_t)
2013
2013
Engelska.
Ingår i: Engineering. - 1947-394X. ; 5:1B, s. 37-43
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Reflector edges, sharp acceptance angles and by-pass diodes introduce large variations in the electrical performance of asymmetrical concentrating photovoltaic/thermal modules over a short incidence angle interval. It is therefore important to quantify these impacts precisely. The impact on the electrical performance of the optical properties of an asymmetrical photovoltaic/thermal CPC-collector was measured in Maputo, Mozambique. The measurements were carried out with the focus on attaining a high resolution incidence angle modifier in both the longitudinal and transversal directions, since large variations were expected over small angle intervals. A detailed analysis of the contribution of the diffuse radiation to the total output was also carried out. The solar cells have an electrical efficiency of 18% while the maximum measured electrical efficiency of the collector was 13.9 % per active glazed area and 20.9 % per active cell area, at 25 °C. Such data make it possible to quantify not only the electrical performance for different climatic and operating conditions but also to determine potential improvements to the collector design. The electrical output can be increased by a number of different measures, e.g. removing the outermost cells, turning the edge cells 90°, dividing each receiver side into three or four parts and directing the tracking, when used, along a north-south axis.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Husbyggnad (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Building Technologies (hsv//eng)

Nyckelord

PVT hybrid
CPC-collector
incidence angle modifier
asymmetric collector
electrical efficiency

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy