Automatic measurement of atrial pacing thresholds in dual-chamber pacemakers: Clinical experience with atrial capture management

Sperzel, J (författare)
Milasinovic, G (författare)
Smith, T W (författare)
visa fler...
Mead, H (författare)
Brandt, Johan (författare)
Lund University,Lunds universitet,Thoraxkirurgi,Sektion II,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Thoracic Surgery,Section II,Department of Clinical Sciences, Lund,Faculty of Medicine
Haisty, W K (författare)
Bailey, J R (författare)
Roelke, M (författare)
Simonson, J (författare)
Englund, J (författare)
Farges, E (författare)
Compton, S (författare)
visa färre...
 (creator_code:org_t)
Elsevier BV, 2005
2005
Engelska.
Ingår i: Heart Rhythm. - : Elsevier BV. - 1547-5271. ; 2:11, s. 1203-1210
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BACKGROUND The Medtronic EnPulse (TM) pacemaker incorporates the new atrial capture management (ACM) algorithm to automatically measure atrial capture thresholds and subsequently manage atrial pacing outputs. OBJECTIVES The purpose of this study was to evaluate the clinical performance of ACM. METHODS Two hundred patients with an indication for a dual-chamber pacemaker underwent implantation. ACM thresholds and manually measured atrial pacing thresholds were assessed at follow-up visits. Clinical equivalence was defined as the ACM-measured threshold being within -0.25 V to +0.5 V of the manually measured threshold. The clinician analyzed all ACM measurements performed in-office for evidence of proarrhythmia. RESULTS All 200 implanted patients had a 1-month visit, and validated manual and in-office ACM threshold data were available for 123 patients. The ACM threshold was 0.595 +/- 0.252 V, and the manual threshold was 0.584 +/- 0.233 V. The mean difference was 0.010 V with a 95% confidence interval of (-0.001, 0.021). The mean difference over all visits was 0.011 V. For all patients, the individual threshold differences were within the range of clinical equivalence at all visits. No atrial arrhythmias were observed during 892 ACM tests in 193 patients. CONCLUSION This study demonstrated that the ACM algorithm is safe, accurate, and reliable over time. ACM was demonstrated to be clinically equivalent to the manual atrial threshold test in all patients at 1 month and over the entire follow-up period of up to 6 months. ACM ensures atrial capture, may save time during follow-up, and can be used to manage atrial pacing outputs.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)

Nyckelord

atrioventricular conduction
atrial chamber reset
automatic atrial threshold measurement
atrial capture management
atrial threshold
test
dual-chamber pacemaker

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy