SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:9e506e54-0dce-46dd-89b5-bf2d50460dbd"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:9e506e54-0dce-46dd-89b5-bf2d50460dbd" > Detection of hydrog...

Detection of hydrogen peroxide using photofragmentation laser-induced fluorescence.

Johansson, Olof (författare)
Lund University,Lunds universitet,Förbränningsfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Combustion Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
Bood, Joakim (författare)
Lund University,Lunds universitet,Förbränningsfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Combustion Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
Aldén, Marcus (författare)
Lund University,Lunds universitet,Förbränningsfysik,Fysiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Combustion Physics,Department of Physics,Departments at LTH,Faculty of Engineering, LTH
visa fler...
Lindblad, Ulf (författare)
Lund University,Lunds universitet,Livsmedelsteknik,Avdelningen för livsmedel och läkemedel,Institutionen för processteknik och tillämpad biovetenskap,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Food Technology, Engineering and Nutrition,Division of Food and Pharma,Department of Process and Life Science Engineering,Departments at LTH,Faculty of Engineering, LTH
visa färre...
 (creator_code:org_t)
2008-01-01
2008
Engelska.
Ingår i: Applied Spectroscopy. - : SAGE Publications. - 1943-3530 .- 0003-7028. ; 62:1, s. 66-72
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Photofragmentation laser-induced fluorescence (PF-LIF) is for the first time demonstrated to be a practical diagnostic tool for detection of hydrogen peroxide. Point measurements as well as two-dimensional (2D) measurements in free-flows, with nitrogen as bath gas, are reported. The present application of the PF-LIF technique involves one laser, emitting radiation of 266 nm wavelength, to dissociate hydrogen peroxide molecules into OH radicals, and another laser, emitting at 282.25 nm, to electronically excite OH, whose laser-induced fluorescence is detected. The measurement procedure is explained in detail and a suitable time separation between photolysis and excitation pulse is proposed to be on the order of a few hundred nanoseconds. With a separation time in that regime, recorded OH excitation scans were found to be thermal and the signal was close to maximum. The PF-LIF signal strength was shown to follow the same trend as the vapor pressure corresponding to the hydrogen peroxide liquid concentration. Thus, the PF-LIF signal appeared to increase linearly with hydrogen peroxide vapor-phase concentration. For 2D single shot measurements, a conservatively estimated value of the detection limit is 30 ppm. Experiments verified that for averaged point measurements the detection limit was well below 30 ppm.

Ämnesord

NATURVETENSKAP  -- Fysik -- Atom- och molekylfysik och optik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Atom and Molecular Physics and Optics (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Johansson, Olof
Bood, Joakim
Aldén, Marcus
Lindblad, Ulf
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Fysik
och Atom och molekyl ...
Artiklar i publikationen
Applied Spectros ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy