SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:lup.lub.lu.se:9ee0dd5b-d734-4932-9e5a-8c8c9bf775ca"
 

Sökning: id:"swepub:oai:lup.lub.lu.se:9ee0dd5b-d734-4932-9e5a-8c8c9bf775ca" > Film cooling perfor...

Film cooling performance under plasma aerodynamic actuation and spoiler ribs of an internal cooling channel based on Suzen model

Sun, Jie (författare)
Northwestern Polytechnic University
Xie, Gongnan (författare)
Northwestern Polytechnic University
Sunden, Bengt (författare)
Lund University,Lunds universitet,Värmeöverföring,Institutionen för energivetenskaper,Institutioner vid LTH,Lunds Tekniska Högskola,Heat Transfer,Department of Energy Sciences,Departments at LTH,Faculty of Engineering, LTH
visa fler...
Wang, Jin (författare)
Hebei University of Technology
visa färre...
 (creator_code:org_t)
Engelska.
Ingår i: Numerical Heat Transfer; Part A: Applications. - 1040-7782.
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In this paper, a plasma actuator (PA), treated by the Suzen model, is introduced into film cooling, and four rows of rectangular ribs are employed in internal cooling. Combined action and individual action of film cooling and internal cooling are then investigated at four blowing ratios (M = 0.25; 0.5; 0.75; 1.0). Results show that (no PA, no ribs) the coolant is ejected from the film hole in a spiral form under the action of internal crossflow, and its distributions are inclined to crossflow direction. When the plasma actuator is opened (no ribs), the strength and scale of the counter-rotating vortex pairs are weakened, and the motion of coolant is accelerated, the average cooling effectiveness shows an increase of 82.4% (M = 0.25), 98.9% (M = 0.5), 33.4% (M = 0.75) and a decrease of 2.1% (M = 1.0), the spanwise cooling effectiveness is raised by 57.3–143.3% for each streamwise position, the flow coefficient is lowered by 1.8–3.2%. Ribs (no PA) interfere with the coolant flow in the internal channel, reducing the rotation degree and exit momentum of the coolant, and greatly eliminate the uneven distribution of coolant along the spanwise direction, resulting in an enhancement of 50.4–162.8% in the spanwise cooling effectiveness and of 59.2% (M = 0.25) and 79.5% (M = 0.5) in average film cooling effectiveness. The effect of combined action (PA plus ribs) is lower than those effects of individual factors, and wall average film cooling effectiveness with PA and ribs exhibits a 62.4% (M = 0.25) and 49.4% (M = 0.5) higher to PA off a case (no PA, no ribs); however, a local or global heat transfer deterioration appears at M = 0.75 and 1.0.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Energiteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Energy Engineering (hsv//eng)

Nyckelord

Film cooling
flow control
internal cooling
plasma aerodynamic actuation
rib

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Sun, Jie
Xie, Gongnan
Sunden, Bengt
Wang, Jin
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Maskinteknik
och Energiteknik
Artiklar i publikationen
Numerical Heat T ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy