Signal quality assessment of f-waves in atrial fibrillation

Henriksson, Mikael (författare)
Lund University,Lunds universitet,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
Petrenas, Andrius (författare)
Kaunas University of Technology
Marozas, Vaidotas (författare)
Kaunas University of Technology
visa fler...
Sandberg, Frida (författare)
Lund University,Lunds universitet,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
Sörnmo, Leif (författare)
Lund University,Lunds universitet,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
visa färre...
 (creator_code:org_t)
2017
2017
Engelska 4 s.
Ingår i: 2017 Computing in Cardiology (CinC). - 2325-8861. - 9781538645550 - 9781538666302
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • Ambulatory ECG recordings are frequently corrupted by artifacts caused by, e.g., muscle activity or moving electrodes, which complicates the analysis of f-waves and motivates signal quality assessment to improve the reliability of f-wave analysis. Although many methods have been developed for assessing the quality of ECG signals in general, no method deals specifically with f-waves. This study proposes a novel signal quality index (SQI), using a modelbased approach for assessment of f-wave signal quality. To evaluate the performance of the SQI, 189 5-s recordings of f-waves from AF patients are studied, as is the same number of recordings with motion artifacts and electrode movements taken from the MIT-BIH Noise Stress Test Database. The signal quality index is capable of discriminating between f-waves and noisy recordings with an accuracy of 98%. The results suggest that the proposed signal quality index correctly identifies noisy recordings, and can be used to improve the reliability of f-wave analysis.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)

Publikations- och innehållstyp

kon (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy